The effect of cannula material on the pain of peripheral intravenous cannulation in the emergency department: A prospective, randomized controlled study

Küçük Resim Yok

Tarih

2012

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Objectives: The present study was undertaken to compare the pain of peripheral IV cannulation (IVC) using a 20-G peripheral biomaterial PEU-Vialon cannula or the 20-G compound FEP-Teflon cannula widely used in clinical practice. Methods: A prospective, randomized, single-blinded, controlled trial was undertaken at the ED of University Hospital. Eighty-nine noncritically ill adult patients who were receiving an IV line as part of their care were enrolled. In each case cannulas were applicated to the antecubital area. Participants rated their pain on a visual analog scale (VAS). The primary outcome was patients pain score, and the secondary outcome was the provider's perception of safety and satisfaction. Results: The two treatment groups did not differ in age, gender or cannulation indication (p>0.05). Mean VAS was 2.80 for PEU and 3.56 for FEP (p=0.061). Mean provider safety scores were 4.84 (4 to 5) in the PEU group and 4.00 (2 to 5) in the FEP group (p=0.0001). Mean provider satisfaction of application scores were 4.65 in the PEU group and 4.56 in the FEP group (p>0.05). Conclusions: Althogh provider safety perception is high, perception of pain has not reduced when inserting PEU-Vialon cannula compared with compound of FEP.

Açıklama

Anahtar Kelimeler

Analgesia, Cannulation, Emergency medicine, Pain, Pain measurement

Kaynak

Turkiye Acil Tip Dergisi

WoS Q Değeri

Scopus Q Değeri

N/A

Cilt

12

Sayı

4

Künye