Interobserver and intraobserver reliability in lower-limb flexibility measurements

dc.contributor.authorAtamaz, F.
dc.contributor.authorOzcaldiran, B.
dc.contributor.authorOzdedeli, S.
dc.contributor.authorCapaci, K.
dc.contributor.authorDurmaz, B.
dc.date.accessioned2019-10-27T21:35:04Z
dc.date.available2019-10-27T21:35:04Z
dc.date.issued2011
dc.departmentEge Üniversitesien_US
dc.description.abstractAim. To describe the inter- and intraobserver reliability of lower extremity flexibility tests, and to explore the effect of sports activity on the results. Methods. A total of 66 subjects consisting of 20 professional athletes, 26 active subjects performing any sporting activity and 20 control subjects were included. Various flexibility tests were performed to determine hamstring, quadriceps and hip adductor muscle flexibility by two examiners blinded to each other for interobserver reliability. Intraobserver reliability of tests were evaluated by one the examiners 1 week later. Inter- and intraobserver reliability was analyzed with intraclass correlation coefficient (ICC), coefficient of variation (CV) and critical difference (CD). Results. ICC analysis showed that inter- and intra-observer reliability results were satisfactory for all measurements. Athletes performed the best results of inter- and intraobserver reliability for flexibility tests in means of CV and CD compared with active and control groups (P<0.05). Popliteal angle measurement was the most reliable one among hamstring flexibility tests where as the least reliable test was chair sit and reach test in all groups. Conclusion. This is the first study evaluating extensively the reliability of flexibility tests in different intensities of sports activity. Flexibility measurements of quadriceps and hip adductor muscles can be used reliably in clinical practice as hamstring flexibility tests. The intensity of performed activity may have an effect on the reliability of flexibility tests.en_US
dc.identifier.endpage694en_US
dc.identifier.issn0022-4707
dc.identifier.issn1827-1928
dc.identifier.issue4en_US
dc.identifier.pmid22212274en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage689en_US
dc.identifier.urihttps://hdl.handle.net/11454/45768
dc.identifier.volume51en_US
dc.identifier.wosWOS:000300036200021en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherEdizioni Minerva Medicaen_US
dc.relation.ispartofJournal of Sports Medicine and Physical Fitnessen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPliabilityen_US
dc.subjectLower extremityen_US
dc.subjectAthletesen_US
dc.titleInterobserver and intraobserver reliability in lower-limb flexibility measurementsen_US
dc.typeArticleen_US

Dosyalar