Femoral signal intensity: A new method for prediction of embolic risk

dc.contributor.authorErcan E.
dc.contributor.authorBaris N.
dc.contributor.authorTengiz I.
dc.contributor.authorErcan H.E.
dc.contributor.authorOnbasili O.A.
dc.contributor.authorDuman C.
dc.contributor.authorCinar C.S.
dc.date.accessioned2019-10-27T08:59:36Z
dc.date.available2019-10-27T08:59:36Z
dc.date.issued2003
dc.departmentEge Üniversitesien_US
dc.description.abstractMitral stenotic patients with left atrial spontaneous echo contrast (LA SEC) are associated with high risk of thromboembolism. The aim of this study was to predict thromboembolic risk in mitral stenotic patients. Femoral artery signal intensity alteration (%) was compared among the groups. Group 1 had severe mitral stenosis with LA SEC and group 2 slight mitral stenosis without LA SEC. Group 3 patients had normal transthoracic echocardiography. Femoral artery longitudinal view was studied with a linear USG probe (7.5 MHz, HP 2500). The femoral cuff was inflated to 300 mmHg, 7-12 cm below the inguinal ligament. Cuff inflation resulted in femoral arterial blood stasis. Intraluminal signal intensity increased in seconds. The femoral signal intensity alteration (%) at 180 seconds was compared to baseline. After femoral cuff inflation, femoral signal intensity alteration (%) was significantly higher in group 1 than groups 2 and 3 (P < 0.001). Group 1 patients had higher thromboembolic risk on the basis of their echocardiographic, clinical, and laboratory parameters. Increased signal intensity alteration (%) can be detected in the femoral artery in mitral stenotic patients with LA SEC. Copyright © 2004 by the Japanese Heart Journal.en_US
dc.identifier.doi10.1536/jhj.44.705en_US
dc.identifier.endpage712en_US
dc.identifier.issn0021-4868
dc.identifier.issue5en_US
dc.identifier.pmid14587652en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage705en_US
dc.identifier.urihttps://doi.org/10.1536/jhj.44.705
dc.identifier.urihttps://hdl.handle.net/11454/27855
dc.identifier.volume44en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.relation.ispartofJapanese Heart Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEmbolic risken_US
dc.subjectMitral stenosisen_US
dc.subjectSpontaneous echo contrasten_US
dc.titleFemoral signal intensity: A new method for prediction of embolic risken_US
dc.typeArticleen_US

Dosyalar