Comparison of conventional and digital radiography systems with regard to radiopacity of root canal filling materials

dc.contributor.authorAkcay I.
dc.contributor.authorIlhan B.
dc.contributor.authorDundar N.
dc.date.accessioned2019-10-26T21:45:30Z
dc.date.available2019-10-26T21:45:30Z
dc.date.issued2012
dc.departmentEge Üniversitesien_US
dc.description.abstractAim To compare the radiopacity of five root filling materials as measured on digitized E-speed films, storage phosphor plate and CCD sensor images. Methodology Radiopacity of Resilon cones and Epiphany, MM-Seal, EndoREZ and AH Plus sealers were investigated. Ten acrylic plates were prepared and filled with the materials. Samples were radiographed together with samples of dentine and an aluminium stepwedge. Images were obtained using E-speed films, Digora storage phosphor plates and Schick CDR CCD sensor. Conventional radiographs were digitized using a desktop scanner. Mean grey values of the materials, stepwedge and dentine were measured using the histogram analysis function of Photoshop 7.0. A graph of radiographic density versus thickness of the aluminium was drawn for each image from which the radiographic densities of the materials were determined in relation to the aluminium thickness. The mean was calculated, and the data were analysed using repeated measures anova and Bonferroni tests (P<0.05). Results There were significant differences between different imaging modalities (P=0.018) and root filling materials (P<0.001). A statistically significant interaction between imaging modality and material was also observed (P<0.001). All materials had radiopacity above 3mm of aluminium regardless of the imaging technique. The radiopacity of Resilon and Epiphany was significantly higher on digital images compared with digitized E-speed film images (P<0.001). Conclusion The choice of imaging system may effect radiopacity measurements. It is possible that radiopacity as recorded on traditional or digitized films is not indicative of the radiopacity as recorded on a digital sensor. © 2012 International Endodontic Journal.en_US
dc.identifier.doi10.1111/j.1365-2591.2012.02026.xen_US
dc.identifier.endpage736en_US
dc.identifier.issn0143-2885
dc.identifier.issue8en_US
dc.identifier.pmid22458866en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage730en_US
dc.identifier.urihttps://doi.org/10.1111/j.1365-2591.2012.02026.x
dc.identifier.urihttps://hdl.handle.net/11454/18511
dc.identifier.volume45en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.relation.ispartofInternational Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDigital radiographyen_US
dc.subjectEndodonticsen_US
dc.subjectRadiopacityen_US
dc.subjectRoot filling materialsen_US
dc.titleComparison of conventional and digital radiography systems with regard to radiopacity of root canal filling materialsen_US
dc.typeArticleen_US