Koroner balon anjioplasti ve stent yerleştirilmesinden sonra oluşan miyokard hasarının araştırılmasında troponin-T ve CK-MB enzimleri
dc.contributor.author | Azem Akıllı | |
dc.contributor.author | Özer Badak | |
dc.contributor.author | Dilek Özmen | |
dc.contributor.author | Sara Habif | |
dc.contributor.author | Cemil Gürgün | |
dc.contributor.author | Filiz Özerkan | |
dc.contributor.author | Mehdi Zoghi | |
dc.contributor.author | Oya Bayındır | |
dc.date.accessioned | 2019-10-26T20:06:32Z | |
dc.date.available | 2019-10-26T20:06:32Z | |
dc.date.issued | 1997 | |
dc.department | Ege Üniversitesi | en_US |
dc.description.abstract | Koroner balon anjioplastiden sonra bazı olgularda kreatin kinaz izoenzim MB (CK-MB) ve Troponin T (TnT) ile saptanabilen miyokard hasarı gelişebildiği ve miyokard hasarını saptamada TnT'nin CK-MB 'ye göre özgünlük ve duyarlılığının daha yüksek olma¬sı nedeniyle avantajlı olduğu bilinmektedir. Çalışmanın amacı son yıllarda daha sık kullanılmakta olan koroner stentlerin de miyokard hasarına yol açıp açmadıklarını saptamak, PTCA ve stent yöntemini bu konuda karşılaştırmak ve bu hasarı saptamada TnT ve CK-MB 'nin değerini araştırmaktır. Çalışmaya yaşları 51±8 olan 15 koroner stent ve 54±9 olan 15 PTCA olgusu olmak üzere 30 olgu alınmıştır. Olguların girişimlerden önce ve girişimlerden sonraki 4, 8, 16. saatlerde serum CK-MB ve TnT düzeyleri ölçüldü, EKG kayıtları alındı, klinik izlemleri yapıl¬dı. TnT için 0.2 ng/ml'nin, CK-MB için 24U/lt'nin üzerindeki değerler patolojik kabul edildi. 16 saatlik izlem döneminde stent uygulanan olguların 10'unda TnT pozitif (%67), 7'sinde ise CK-MB pozitif (%47) idi (p<0.05). PTCA yapılan olgularda ise TnT 9 olguda (%60), CK-MB 5 olguda (%33) pozitif bulundu (p<0.05). TnT pozitifliği stent ve PTCA ol¬gularında sırası ile %67 ve %60 (p=ns), CK-MB pozitifliği stent olgularında %47, PTCA olgularında %33 (p=ns) bulunmuştur. Bu çalışmada koroner stentlerin de implantasyondan sonra minör miyokard hasarı oluşturabilecekleri ve bu hasarı saptamada TnT testinin CK-MB 'ye göre daha yüksek tanı duyarlılığına sahip olduğu anlaşılmıştır. | en_US |
dc.description.abstract | Troponin-T and Creatin Kinase-MB in Detecting Myocardial Injury After Coronary Stent Placement and Balloon Angioplasty . It has been known that there were be minor myocardial injury detectable with creatine kinase isoenzyme MB (CK-MB) and Troponin T (TnT) tests after coronary baloon angioplasty. TnT had an advantage over CK-MB because of it's higher cardiospesifity and sensitivity. This study was designed to test the coronary stenting may lead myocardial damage and to compare PTCA and coronary stenting procedures in this respect. We also invastigated the diagnostic efficacy of the TnT and CK-MB to detect myocardial injury. Study population consisted of 30 patients: There were 15 patients (mean age 51±8) in stent group and 15 patients (mean age 54±9) in PTCA group. There was no difference between the groups with respect to demographic data. Serial blood samples were drawn for measurement of serum TnT and CK-MB levels before the procedure, and thereafter at 4, 8, 16 hours. At same time 12 lead ECG was also recorded. TnT levels >0.2 ng/ml and CK-MB levels >24 U/lt were assumed to be an abnormal increase and indicative for myocardial In the stent group,. 10 patients (67%) had positive TnT and 7 patients (4 7%) had positive CK-MB levels after procedure (p<0.05). In the PTCA group, 9 patients (60%) had positive TnT and 5 patients (33%) had positive CK-MB levels after procedure (p<0.05). Positive TnT values detected in stent and PTCA patients were 67% and 60% with respectively (p=ns). Positive CK-MB values were detected 47% in the stent group and 33% in the PTCA group (p=ns). This study demonstrates both coronary stent implantation and PTCA procedures cause minor myocardial damage approximately %70 of the patients detectable with TnT. TnT test has higher diagnostic sensitivity than CK-MB for detecting this myocardial damage. | en_US |
dc.identifier.endpage | 307 | en_US |
dc.identifier.issn | 1300-4778 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 300 | en_US |
dc.identifier.uri | https://app.trdizin.gov.tr/makale/TkRJMk9EQXc= | |
dc.identifier.uri | https://hdl.handle.net/11454/15401 | |
dc.identifier.volume | 4 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.language.iso | tr | en_US |
dc.relation.ispartof | MN Kardiyoloji | en_US |
dc.relation.publicationcategory | Diğer | en_US] |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Kalp ve Kalp Damar Sistemi | en_US |
dc.title | Koroner balon anjioplasti ve stent yerleştirilmesinden sonra oluşan miyokard hasarının araştırılmasında troponin-T ve CK-MB enzimleri | en_US |
dc.title.alternative | Troponin-T and creatin kinase-MB in detecting myocardial injury after coronary stent placement and balloon angioplasty | en_US |
dc.type | Other | en_US |