Sürtünmesel kilitlenen implant-dayanak bağlantısının yüzey elementel analizinin (EDX) ve pürüzlülüğünün, mikro boşluk ve dayanak yer değiştirme miktarının in-vitro incelenmesi

dc.authorid0000-0001-7694-9106en_US
dc.contributor.advisorGökçe, Bülent
dc.contributor.authorTangül, Mustafa Burak
dc.date.accessioned2022-06-22T12:30:15Z
dc.date.available2022-06-22T12:30:15Z
dc.date.issued2021en_US
dc.date.submitted2021
dc.departmentEge Üniversitesi, Sağlık Bilimleri Enstitüsü, Protetik Diş Tedavisi Ana Bilim Dalıen_US
dc.description.abstractİmplant ve dayanaklar arasındaki bağlantının stabilitesi üzerine yapılmış sayısız çalışma bulunmaktadır. Bağlantıda vida kullanmayan implant-dayanak sistemleri sürtünmesel kilitlenen sistemlerdir. Bu sistemlerde bağlantıya katılan yüzeyler belli bir açıda koniklik göstermektedir. Çalışmamız için soğuk kilitlenme dizaynına sahip 2 mm, 2,5 mm ve 3 mm bağlantı çapında toplam altmış üç adet implant-dayanak örneği üretilmiştir. Dayanaklar implantlara yerleştirilmeden önce ve yerleştirilip üzerlerine üç, altı ve on iki kere vurulduktan sonra implantlardan ayrılarak dayanak post yüzeylerinin çevresel taramalı elektron mikroskobunda yüzey pürüzlülüğü ve EDX analizleri yapılmıştır. Bununla birlikte her vuruş sayısı sonrası dayanakların implant kuyularına gömülme miktarları optik ölçüm cihazında ölçülmüştür. Örneklerin üç, altı ve on iki vuruş sonrası bağlantı bölgelerindeki mikro boşluk miktarlarının analizi çevresel taramalı elektron mikroskobunda yapılmıştır. Elde edilen sonuçlar bağlantı bölgesindeki mikro boşluk miktarlarının bakteri penetrasyonuna izin vermeyen düzeylerde olduğunu, bağlantı yüzeylerindeki yüzey pürüzlülüğünün vuruş sayıları sonrasında arttığını, bağlantı yüzeylerindeki kimyasal bileşenlerin değişimlerinin stabil olduğunu ve dayanakların her vuruş sayısı sonrasında implant kuyularına düzenli şekilde gömüldüğünü fakat üç vuruş sonrasındaki gömülme miktarlarında istatistiksel olarak anlamlı fark olmadığını göstermiştir.en_US
dc.description.abstractThere are numerous studies on the stability of the connection between the implant and abutments. Implant-abutment connection systems that do not use screws in the connection are frictional locking taper systems. In these systems, the surfaces participating in the connection show a conicity at a certain angle. For our study, a total of sixty-three implant-abutment specimens with a cold welding design with 2 mm, 2,5 mm and 3 mm connection diameters were produced. Before the abutments were placed on the implants, and after they were placed and tapped three, six and twelve times, they were separated from the implants and surface roughness and EDX analyzes were performed on the abutment post surfaces using an environmental scanning electron microscope. The amount of sinking of the abutments after each tapp was measured in the optical measuring device. The analysis of the micro-gaps in the connection areas of the samples after three, six and twelve tapps was made by the environmental scanning electron microscope. The results showed that the amount of micro-gaps in the connection area decreased to levels that do not allow bacterial penetration, the surface roughness of the connection surfaces increased after each tapping, the surface chemical components were stable and there was no significant difference in the amount of sinking of the abutments after three hits.en_US
dc.identifier.urihttps://hdl.handle.net/11454/75009
dc.language.isotren_US
dc.publisherEge Üniversitesi, Sağlık Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectYüzey Pürüzlülüğüen_US
dc.subjectMikro Boşluken_US
dc.subjectEDX Analizien_US
dc.subjectDayanak Yer Değiştirmeen_US
dc.subjectSurface Roughnessen_US
dc.subjectMicro Gapen_US
dc.subjectEDX Analysisen_US
dc.subjectAbutment Displacementen_US
dc.titleSürtünmesel kilitlenen implant-dayanak bağlantısının yüzey elementel analizinin (EDX) ve pürüzlülüğünün, mikro boşluk ve dayanak yer değiştirme miktarının in-vitro incelenmesien_US
dc.title.alternativeIn-vitro evaluation of surface elemental analysis (EDX) and roughness, amount of micro-gaps and abutment displacement of frictional locking taper implant-abutment connectionen_US
dc.typeDoctoral Thesisen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
mustafaburaktangul2021.pdf
Boyut:
8.6 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Doktora tez dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: