Pre-clinic study of radiopharmaceutical for Covid-19 inactivation: Dose distribution with Monte Carlo Simulation

Küçük Resim Yok

Tarih

2022

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Pergamon-Elsevier Science Ltd

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Monte Carlo simulation method and Nuclear Medicine MIRD method were used to evaluate the effect of ra-diopharmaceuticals on Covid-19 disease. The mean absorbed organ dose in the target organ and gamma radi-ation emitter attenuation properties such as linear attenuation coefficients, energy absorption build-up factors (EABF), exposure build-up factors (EBF), and relative dose distributions (RDD) were examined. The results showed that radiopharmaceuticals containing gamma radiation emitters which are densely ionizing charged particles induced membrane damage and produced protein damage.

Açıklama

Anahtar Kelimeler

Covid-19, Monte Carlo simulation, Relative dose distribution, Gamma radiation emitter, Tc-99m, Bioactive Glasses, Radiation, Therapy, Gamma, Infections

Kaynak

Applied Radiation and Isotopes

WoS Q Değeri

Q2

Scopus Q Değeri

Q3

Cilt

188

Sayı

Künye