Işınlama parametrelerinin kanal patlarının radyoopasitesi üzerine etkisi / The effect of exposure parameters on the radiopacity of root canal

dc.contributor.authorErinç Önen
dc.contributor.authorB. Güniz Baksı
dc.contributor.authorBilge Hakan Şen
dc.date.accessioned2019-10-26T19:34:24Z
dc.date.available2019-10-26T19:34:24Z
dc.date.issued2012
dc.departmentEge Üniversitesien_US
dc.description.abstractAmaç: Farklı kilovoltaj, miliamper ve ışınlama süresi parametrelerinin geleneksel radyografide kök kanal patının radyoopasitesi üzerine etkisini değerlendirmektir. Gereç ve Yöntem: Çalışmada Diaket ve MM Seal kullanıldı. Her iki cins kanal patından birer örnek ve alüminyum penetrometre, D-hızında okluzal bir film kullanılarak 60 ,70 kVp; 7,8 mA; 0.40, 0.50, 0.60 sn ışınlama parametreleri kullanılarak radyografları elde edildi. Kanal patlarının radyografik densitesi ve Al penetrometrenin tüm basamakları dijital transmisyon densitometrisi ile değerlendirildi. Kilovoltaj, miliamper ve ışınlama süresi göz önüne alındığında kanal patlarının radyodensiteleri arasındaki farklar ve her üç faktörün birbirleriyle olan ilişkisi üçlü varyans analizi kullanılarak karşılaştırıldı. Bulgular: Tüm ışınlama parametrelerindeMMSeal’in Diakete göre anlamlı olarak daha radyoopak olduğu saptandı (p<0,05). Kilovolt, miliamper ve ışınlama süresi değişikliği kanal patlarının radyoopasitesinde herhangi bir fark yaratmadı (p>0.05) Sonuç: Her iki kök kanal patı da ISO tarafından önerilen radyoopasite standartları içindedir. KvP, mA ve ışınlama süresi parametrelerindeki minör değişiklikler radyografik densite üzerinde anlamlı bir farklılık oluşturmamaktadır.en_US
dc.description.abstractObjective: The aim of this study was to evaluate change in radiopacity of two root canal sealers with the change in exposure parameters (kilovoltage, milliampere and exposure time) using conventional film radiography. Material and Method: The root canal sealers used were Diaket and MM Seal. Standard disks of 2 different sealers were exposed together with an aluminum (Al) step wedge by using a D-speed occlusal film. Each sample was radiographed using 60 and 70 kVp, 7 and 8 mA with three different exposure times (0.40, 0.50, 0.60 s). Optical density of the sealers and the Al step-wedge was evaluated by transmission densitometry, The radiographic density of each specimen was measured and correlated with the equivalent thickness of aluminum. Three-way analysis of variance was used to compare the differences between groups (p=0.05). Results: No significant differences were found in radiopacities of sealers with respect to different kVp, mA and exposures used in this study (p&gt;0.05). At all radiologic parameters used in this study MM Seal was more radiopaque than Diaket (p&lt;0.05). Conclusion: Varying the kVp, mA and exposure time did not significantly affect the radiographic density of Diaket and MM Seal.en_US
dc.identifier.endpage104en_US
dc.identifier.issn1300-3100
dc.identifier.issue2en_US
dc.identifier.startpage99en_US
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TVRReE1UUTRPQT09
dc.identifier.urihttps://hdl.handle.net/11454/10964
dc.identifier.volume29en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.relation.ispartofGazi Üniversitesi Diş Hekimliği Fakültesi Dergisi (.Acta Odontologica Turcica)en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.titleIşınlama parametrelerinin kanal patlarının radyoopasitesi üzerine etkisi / The effect of exposure parameters on the radiopacity of root canalen_US
dc.title.alternativeThe effect of exposure parameters on the radiopacity of root canalen_US
dc.typeArticleen_US