Comparative evaluation of desensitizing agents on shear bond strength of zirconia to dentin
dc.authorid | 0000-0003-2779-4923 | |
dc.authorid | 0000-0003-1343-8928 | |
dc.contributor.author | Cotert, Irem | |
dc.contributor.author | Aytug, Merve | |
dc.contributor.author | Cotert, H. Serdar | |
dc.date.accessioned | 2025-03-19T07:32:39Z | |
dc.date.available | 2025-03-19T07:32:39Z | |
dc.date.issued | 2024 | |
dc.department | Ege Üniversitesi, Diş Hekimliği Fakültesi | |
dc.description.abstract | Background The purpose of the study is to evaluate the effect of 7 different desensitizing agents on the shear bond strength (SBS) of zirconia restorations to dentin with a self-adhesive resin cement and determine the failure modes. Methods Eighty molars' occlusal surfaces were ground to expose dentin and were randomly divided into 8 groups (n = 10): 1. Gluma (HEMA/Glutaraldehyde) 2. Bifluoride (Sodium Fluoride/Calcium Fluoride) 3. Admira (Bis-GMA/HEMA) 4. Smart Protect (Glutaraldehyde) 5. Teethmate (Tetracalcium phosphate, Dicalcium phosphate) 6. Clinpro White (Sodium fluoride) 7. BisBlock (Oxalic acid) and 8. Control (No-treatment). After applying the agent, a self-adhesive resin cement (Rely-X U200) was used to lute zirconia discs (4 mm height and 4 mm diameter) to dentin. After stored in distilled water at 37 degrees C for 24 h, all groups were thermocycled for 2500 cycles between 5 +/- 2 degrees C and 55 +/- 2 degrees C. Specimens were submitted to SBS test with a universal testing machine at a crosshead speed of 0.5 mm/min until failure. SBS values were compared with ANOVA. Post-hoc multiple comparisons were performed with Dunnett T3. The failure modes of specimens were examined with stereomicroscope at a magnification of 20X and the distribution of the failure modes were evaluated with Pearson Chi-Square test. Results Regarding mean SBS values in MPa's; Admira (10.70 +/- 3.99), Smart Protect (9.62 +/- 3.93), and Gluma (8.90 +/- 3.76) treatments showed higher SBS values compared to control group (p < .05) according to ANOVA. The SBS values of Teethmate (5.31 +/- 2.37) and Clinpro White (4.32 +/- 2.44) were higher than control group but the difference was not found significant (p > .05). BisBlock (2.33 +/- 1.94) and Bifluouride (1.60 +/- 1.47) groups showed the lowest SBS values but their difference between control group was not found statistically significant (p > .05). Most specimens showed adhesive failure but no statistically significant difference was found in the distributions of failure modes according to Chi-square test. Conclusion Within the limitation of the study; Admira, Smart Protect, and Gluma increased the SBS of the zirconia restorations to dentin and can be recommended to use on prepared dentin surfaces prior to the cementation. | |
dc.identifier.citation | Çötert, İ., Aytuğ, M., & Çötert, H. S. (2024). Comparative evaluation of desensitizing agents on shear bond strength of zirconia to dentin. ( No. 24).BioMed Central Ltd. | |
dc.identifier.doi | 10.1186/s12903-024-05106-8 | |
dc.identifier.endpage | 9 | |
dc.identifier.issn | 1472-6831 | |
dc.identifier.issue | 1 | |
dc.identifier.pmid | 39563267 | |
dc.identifier.scopus | 2-s2.0-85209357011 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 1 | |
dc.identifier.uri | https://doi.org/10.1186/s12903-024-05106-8 | |
dc.identifier.uri | https://hdl.handle.net/11454/116797 | |
dc.identifier.volume | 24 | |
dc.identifier.wos | WOS:001360389300003 | |
dc.identifier.wosquality | Q1 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Cotert, Irem | |
dc.institutionauthor | Aytug, Merve | |
dc.institutionauthor | Cotert, H. Serdar | |
dc.institutionauthorid | 0000-0003-2779-4923 | |
dc.institutionauthorid | 0000-0003-1343-8928 | |
dc.language.iso | en | |
dc.publisher | BMC | |
dc.relation.ispartof | BMC Oral Health | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Dentistry | |
dc.subject | Desensitizers | |
dc.subject | Post-operative hypersensitivity | |
dc.subject | Shear bond strength | |
dc.title | Comparative evaluation of desensitizing agents on shear bond strength of zirconia to dentin | |
dc.type | Article |
Dosyalar
Lisans paketi
1 - 1 / 1
Küçük Resim Yok
- İsim:
- license.txt
- Boyut:
- 1.17 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: