The evaluation of the removal forces on the conus crowned telescopic prostheses with the finite element analysis (FEA)

Küçük Resim Yok

Tarih

2002

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Blackwell Publishing Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The removable partial dentures supported by the telescopic crowns are an alternative for directly retained removable partial dentures. The stress distribution on the retainers and the surrounding tissues created by the telescopic and conus crowns of different sizes ( 4, 5, 6 mm) and taper (0degrees, 2degrees, 4degrees, 6degrees) was investigated with the finite element analysis (FEA) method. The stress values obtained were evaluated either as strain or tensional forces. The loosening force of the secondary crown being determined as 5 N, the increase in tension of the dentine, metal structure, alveolar bone, periodontal ligament and the pulp were determined by the increasing height and taper. The reason for the increase in tensional forces with increasing taper was the result of the constant loosening force of 5 N applied in all experimental models. The strain was more effective than the tension with the highest stress being in the cervical region of the metal structure. The aim of this study was to determine the force exerted on the teeth and surrounding tissues by the loosened secondary crown.

Açıklama

Anahtar Kelimeler

removal forces, conus crowns, finite element analysis

Kaynak

Journal of Oral Rehabilitation

WoS Q Değeri

Q4

Scopus Q Değeri

N/A

Cilt

29

Sayı

11

Künye