A method to enhance coincidence time resolution with applications for medical imaging systems (TOF/PET)

dc.contributor.authorErmis, E. E.
dc.contributor.authorCeliktas, C.
dc.contributor.authorPilicer, E.
dc.date.accessioned2019-10-27T22:16:34Z
dc.date.available2019-10-27T22:16:34Z
dc.date.issued2014
dc.departmentEge Üniversitesien_US
dc.description.abstractA coincidence timing spectrometer was assembled using NaI(Tl) inorganic and BC418 type organic (plastic) scintillation detectors. The constant fraction timing method was used. Coincidence time resolution values of the detectors, which have great importance in TOF/PET measurements, were obtained separately. The resolutions were enhanced using a different method in a start-stop coincidence spectrometer: the signals from the start detectors were delayed. The results from the FLUKA Monte Carlo simulation code agreed well with the experimental results. (C) 2014 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipTUBITAK, the Scientific and Technological Research Council of TURKEYTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [197T087]; EBILTEM, Center of Science and Technology, Ege UniversityEge University [99 BIL 001]en_US
dc.description.sponsorshipThis work was supported by TUBITAK, the Scientific and Technological Research Council of TURKEY under Project No. 197T087 and by EBILTEM, Center of Science and Technology, Ege University under Project No. 99 BIL 001.en_US
dc.identifier.doi10.1016/j.radmeas.2014.01.013
dc.identifier.endpage59en_US
dc.identifier.issn1350-4487
dc.identifier.issn1350-4487en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage52en_US
dc.identifier.urihttps://doi.org/10.1016/j.radmeas.2014.01.013
dc.identifier.urihttps://hdl.handle.net/11454/50295
dc.identifier.volume62en_US
dc.identifier.wosWOS:000334003200010en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofRadiation Measurementsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectNaI(Tl) inorganic scintillation detectoren_US
dc.subjectBC418 type plastic scintillation detectoren_US
dc.subjectFLUKA Monte Carlo simulation programen_US
dc.subjectTOF/PETen_US
dc.titleA method to enhance coincidence time resolution with applications for medical imaging systems (TOF/PET)en_US
dc.typeArticleen_US

Dosyalar