dc.description.abstract | In this study, for the first time a model electrochemical kit was constructed for the detection of a functional polymorphism in catechol-O-methyl transferase (COMT) gene which is important for diagnosis of neuropsychiatric disorders as Alzheimer disease. The disposable pencil graphite electrode (PGE) is designed as a kit and the probe DNA covered PGE can detect single nucleotide polymorphisms (SNPs) from real samples based on the guanine oxidation signal even after 5 months of kit preparation (150 days durability).The detection limit (S/N=3) of the biosensor was calculated as 1.18pmol of synthetic target sequence and 6.09x10(5) molecules of real samples in 30min detection time. | en_US |
dc.description.sponsorship | Ege University, Faculty of Pharmacy, Project CoordinationEge University [10 ECZ 022] | en_US |
dc.description.sponsorship | D.O.A acknowledges technical support from the Pharmaceutical Sciences Research Centre (FABAL) of Ege University, Faculty of Pharmacy. The authors acknowledge the financial support from Ege University, Faculty of Pharmacy, Project Coordination (Project number: 10 ECZ 022). | en_US |
dc.identifier.doi | 10.1002/elan.201300386 | |
dc.identifier.endpage | 2676 | en_US |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.issn | 1040-0397 | en_US |
dc.identifier.issn | 1521-4109 | en_US |
dc.identifier.issue | 12 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 2668 | en_US |
dc.identifier.uri | https://doi.org/10.1002/elan.201300386 | |
dc.identifier.uri | https://hdl.handle.net/11454/48888 | |
dc.identifier.volume | 25 | en_US |
dc.identifier.wos | WOS:000328326100013 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wiley-V C H Verlag Gmbh | en_US |
dc.relation.ispartof | Electroanalysis | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Electrochemical DNA biosensor | en_US |
dc.subject | Point-of-care test | en_US |
dc.subject | Ready-to-use kit design | en_US |
dc.subject | Single nucleotide polymorphism | en_US |
dc.subject | Catechol-O-methyl transferase (COMT) Val108 | en_US |
dc.subject | 158Met polymorphism | en_US |
dc.title | A Ready-to-Use Electrochemical Kit Design for the Diagnosis of Single Nucleotide Polymorphisms | en_US |