Comparison of three-dimensional ultrasound and magnetic resonance imaging diagnosis in surgically proven Müllerian duct anomaly cases

dc.contributor.authorErgenoglu A.M.
dc.contributor.authorSahin Ç.
dc.contributor.authorŞimşek D.
dc.contributor.authorAkdemir A.
dc.contributor.authorYeniel A.Ö.
dc.contributor.authorYerli H.
dc.contributor.authorSendag F.
dc.date.accessioned2019-10-27T08:20:41Z
dc.date.available2019-10-27T08:20:41Z
dc.date.issued2016
dc.departmentEge Üniversitesien_US
dc.description.abstractObjective To determine and compare the diagnostic accuracy of 3-dimensional ultrasound (3D US) and magnetic resonance imagining (MRI) in patients with surgically diagnosed Mullerian duct anomaly (MDA). Study design Charts of patients with MDA were retrospectively evaluated. Patients who underwent both laparoscopic and hysteroscopic surgery and had 3D US and MRI examinations were included in the study. The diagnoses achieved via 3D US and MRI were compared with the surgical diagnoses to determine the diagnostic accuracy of these imagining techniques. Results Twenty-nine patients were included in the study. Three-dimensional ultrasound detected 28 out of 29 (96%) patients correctly. Only one patient was diagnosed with a uterine septum instead of uterine arcuatus. Magnetic resonance imaging detected 23 out of 29 patients correctly (79%). The Kappa indexes of the 3D US and MRI were 0.896 and 0.592, respectively. Conclusion Our results indicate that 3D US has a higher diagnostic accuracy level than MRI in evaluating MDA, especially when used in experienced hands. However, additional, well-designed studies are needed to better compare the diagnostic accuracy of the 3D US and MRI. © 2015 Published by Elsevier Ireland Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.ejogrb.2015.11.010en_US
dc.identifier.endpage26en_US
dc.identifier.issn0301-2115
dc.identifier.pmid26699099en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage22en_US
dc.identifier.urihttps://doi.org/10.1016/j.ejogrb.2015.11.010
dc.identifier.urihttps://hdl.handle.net/11454/25765
dc.identifier.volume197en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherElsevier Ireland Ltden_US
dc.relation.ispartofEuropean Journal of Obstetrics and Gynecology and Reproductive Biologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMagnetic resonance imagingen_US
dc.subjectMüllerian duct anomalyen_US
dc.subjectThree-dimensional ultrasonographyen_US
dc.titleComparison of three-dimensional ultrasound and magnetic resonance imaging diagnosis in surgically proven Müllerian duct anomaly casesen_US
dc.typeArticleen_US

Dosyalar