Yangın görmüş betona gömülü çelik kompozit elemanların bileşik eğilme etkisi altında performansının deneysel ve nümerik olarak değerlendirilmesi
dc.contributor.author | Ercan, Emre | |
dc.contributor.investigator | Arısoy, Bengi | |
dc.contributor.investigator | Nuhoğlu, Ayhan | |
dc.contributor.investigator | Hızal, Çağlayan | |
dc.contributor.investigator | Pekedis, Mahmut | |
dc.contributor.investigator | Avcı, Muhammed Serdar | |
dc.date.accessioned | 2025-06-17T13:10:29Z | |
dc.date.available | 2025-06-17T13:10:29Z | |
dc.date.issued | 2024 | |
dc.department | Ege Üniversitesi, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü | |
dc.description.abstract | Bu çalışmada, yangın görmüş betona gömülü çelik kompozit kolonların performans analizi deneysel verilerle desteklenerek gerçekleştirilmiştir. Deneysel çalışma, laboratuvar ortamında konut yangını şartlarını temsil eden ortalama 550°C sıcaklıkta uygulanmıştır. Bu koşullarda elemanlar ısıtılmış ve sonrasında bileşik eğilme etkisinde yüklenerek dayanım değerlendirmesi yapılmıştır. Deneysel veriler, ABAQUS programında modelleme için temel oluşturmuştur. Çalışmanın amacı, farklı dayanımlara sahip iki beton türü olan 25 MPa ve 40 MPa için yangın görmüş betona gömülü çelik kompozit kolonların davranışını incelemektir. Eleman kesit tasarımı için araştırmacıların daha önceki projelerinde kullandıkları 20cmx20cm boyutlarındaki beton kesiti ve IPE100 çelik profil tercih edilmiştir. Bu doğrultuda biri kontrol elemanı olmak üzere, her bir beton dayanımı için dört deney elemanı ve toplamda sekiz numune oluşturulmuştur. Elemanlar, eksenel basınç ve eğilme yükü kombinasyonuna maruz bırakılmıştır, böylece elemanların hem kolon hem de kiriş olarak kullanılma durumundaki performansları değerlendirilmiştir. Yangın görmüş betonun mekanik özelliklerindeki değişiklikler, kompozit kolonların taşıma kapasitesi üzerindeki etkileri açısından incelenmiştir. Çalışma sonuçları, yangın görmüş betona gömülü çelik kompozit kolonların yük taşıma kapasitelerinde azalma olduğunu göstermiştir. Bu azalmanın derecesi, farklı dayanım değerlerine sahip beton türleri için ayrı ayrı belirlenmiştir ve değerlendirilmiştir. | |
dc.description.abstract | In this study, the performance analysis of steel composite columns embedded in concrete subjected to fire was carried out supported by experimental data. The experimental study was conducted in the laboratory at an average temperature of 550°C, which is representative of residential fire conditions. Under these conditions, the members were heated and then loaded in combined flexural and axial load to evaluate their strength. The experimental data formed the basis for modeling in the ABAQUS program. The aim of the study was to investigate the behavior of steel composite columns embedded in fire-exposed concrete for two concrete types with different strengths, 25 MPa and 40 MPa. For the section design, a 20cmx20cm concrete section and an IPE100 steel profile, which were used by the researchers in their previous projects, were chosen. Accordingly, four experimental elements for each concrete strength and eight specimens in total were produced, one of which was a control element. The elements were subjected to a combination of axial compressive and flexural loading to evaluate their performance when used as both columns and beams. Changes in the mechanical properties of the fired concrete were investigated for their effect on the bearing capacity of the composite columns. The results of the study showed a reduction in the load carrying capacity of steel composite columns embedded in fire-exposed concrete. The degree of this reduction was determined and evaluated separately for concrete types with different strength values. | |
dc.identifier.uri | https://hdl.handle.net/11454/117571 | |
dc.language.iso | tr | |
dc.publisher | Ege Üniversitesi | |
dc.relation.publicationcategory | Project | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Betona gömülü çelik kompozit kolon | |
dc.subject | yangın etkisi altında performans | |
dc.subject | sonlu elemanlar analizi | |
dc.subject | bileşik e ilme | |
dc.subject | 4-noktalı yükleme testi. | |
dc.subject | Steel composite columns | |
dc.subject | performance under fire effect | |
dc.subject | finite element method | |
dc.subject | combined bending | |
dc.subject | 4-point loading test. | |
dc.subject.classification | 26343 | |
dc.title | Yangın görmüş betona gömülü çelik kompozit elemanların bileşik eğilme etkisi altında performansının deneysel ve nümerik olarak değerlendirilmesi | |
dc.type | Project |