Electrochemical Monitoring of Interaction of Temozolamide with DNA by Graphene Oxide Modified Single-Use Electrodes
dc.authorid | Erdem, Arzum/0000-0002-4375-8386 | |
dc.authorid | UNAL, DIDEM NUR/0000-0002-3300-138X | |
dc.authorid | Eksin, Ece/0000-0001-7175-2857 | |
dc.authorscopusid | 55845006300 | |
dc.authorscopusid | 57470955100 | |
dc.authorscopusid | 57194853154 | |
dc.authorscopusid | 7004459748 | |
dc.authorwosid | Unal, Didem Nur/AGJ-4973-2022 | |
dc.authorwosid | Erdem, Arzum/X-1925-2019 | |
dc.contributor.author | Eksin, Ece | |
dc.contributor.author | Isin, Deniz | |
dc.contributor.author | Unal, Didem Nur | |
dc.contributor.author | Erdem, Arzum | |
dc.date.accessioned | 2023-01-12T20:03:08Z | |
dc.date.available | 2023-01-12T20:03:08Z | |
dc.date.issued | 2022 | |
dc.department | N/A/Department | en_US |
dc.description.abstract | Graphene oxide (GO) modified single-use pencil graphite electrodes (PGEs) were used for electrochemical monitoring of surface confined interaction between Temozolamide (TMZ) and calf thymus double stranded DNA (ctdsDNA). First, the PGE surface was activated by EDC/NHS (1-ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-hydroxysuccinimide) as covalent agents (CA). Then, modification of GO was done onto the surface of chemically activated PGE surface to obtain CA-GO-PGEs. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy studies were used to establish the interfacial electron transfer of the electrodes. The optimization of experimental conditions was carried out via CV technique followed by electrochemical examination of the interaction of TMZ with ctdsDNA. (c) 2022 The Electrochemical Society (ECS). Published on behalf of ECS by IOP Publishing Limited. | en_US |
dc.description.sponsorship | Turkish Academy of Sciences (TUBA) | en_US |
dc.description.sponsorship | A.E. would like to express her gratitude to the Turkish Academy of Sciences (TUBA) as a Principal member for its partial support. | en_US |
dc.identifier.doi | 10.1149/1945-7111/ac4db1 | |
dc.identifier.issn | 0013-4651 | |
dc.identifier.issn | 1945-7111 | |
dc.identifier.issn | 0013-4651 | en_US |
dc.identifier.issn | 1945-7111 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-85125503717 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.uri | https://doi.org/10.1149/1945-7111/ac4db1 | |
dc.identifier.uri | https://hdl.handle.net/11454/77662 | |
dc.identifier.volume | 169 | en_US |
dc.identifier.wos | WOS:000754062100001 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Electrochemical Soc Inc | en_US |
dc.relation.ispartof | Journal Of The Electrochemical Society | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Hplc Method | en_US |
dc.subject | Rat Plasma | en_US |
dc.subject | Temozolomide | en_US |
dc.subject | Hybridization | en_US |
dc.subject | Chitosan | en_US |
dc.subject | Behavior | en_US |
dc.subject | Drug | en_US |
dc.title | Electrochemical Monitoring of Interaction of Temozolamide with DNA by Graphene Oxide Modified Single-Use Electrodes | en_US |
dc.type | Article | en_US |