Application of experimental design on determination of aluminum content in saline samples by adsorptive cathodic stripping voltammetry
dc.contributor.author | Yilmaz, Sinan | |
dc.contributor.author | Ozturk, Betul | |
dc.contributor.author | Ozdemir, Durmua | |
dc.contributor.author | Eroglu, Ahmet Emin | |
dc.contributor.author | Ertas, Fatma Nil | |
dc.date.accessioned | 2019-10-27T21:54:48Z | |
dc.date.available | 2019-10-27T21:54:48Z | |
dc.date.issued | 2013 | |
dc.department | Ege Üniversitesi | en_US |
dc.description.abstract | Adsorptive cathodic stripping voltammetric determination of aluminum at ng mL(-1) levels in salt samples based on the metal complexation with Calcon (1-(2-hydroxynaphthylazo)-2 naphthol-4-sulfonic acid) and the subsequent adsorptive deposition onto a hanging mercury drop electrode was studied. Central composite design was used as a design method. Several chemical and instrumental parameters (pH, ligand concentration, deposition time, deposition potential, and complexing time) were involved in the experimental design. Analytical parameters such as repeatability, linearity, and accuracy were also investigated and the detection limit was found as 0.32 ng mL(-1). | en_US |
dc.description.sponsorship | Ege UniversityEge University [2004 Fen 071] | en_US |
dc.description.sponsorship | The authors gratefully acknowledge financial support from the Ege University research fund (Project no: 2004 Fen 071). | en_US |
dc.identifier.doi | 10.3906/kim-1204-56 | |
dc.identifier.endpage | 324 | en_US |
dc.identifier.issn | 1300-0527 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 316 | en_US |
dc.identifier.uri | https://doi.org/10.3906/kim-1204-56 | |
dc.identifier.uri | https://hdl.handle.net/11454/48137 | |
dc.identifier.volume | 37 | en_US |
dc.identifier.wos | WOS:000317819800015 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.language.iso | en | en_US |
dc.publisher | Scientific Technical Research Council Turkey-Tubitak | en_US |
dc.relation.ispartof | Turkish Journal of Chemistry | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Aluminum | en_US |
dc.subject | Calcon | en_US |
dc.subject | adsorptive cathodic stripping voltammetry | en_US |
dc.subject | central composite design | en_US |
dc.title | Application of experimental design on determination of aluminum content in saline samples by adsorptive cathodic stripping voltammetry | en_US |
dc.type | Article | en_US |