Arm circumference: Its importance for dialysis patients in the obesity era

dc.contributor.authorAkpolat T.
dc.contributor.authorKaya C.
dc.contributor.authorUtaş C.
dc.contributor.authorArinsoy T.
dc.contributor.authorTaşkapan H.
dc.contributor.authorErdem E.
dc.contributor.authorYilmaz M.E.
dc.contributor.authorAtaman R.
dc.contributor.authorBozfakioglu S.
dc.contributor.authorÖzener C.
dc.contributor.authorKarayaylali I.
dc.contributor.authorKazancioglu R.
dc.contributor.authorÇamsari T.
dc.contributor.authorYavuz M.
dc.contributor.authorErsoy F.
dc.contributor.authorDuman S.
dc.contributor.authorAteş K.
dc.date.accessioned2019-10-27T08:23:29Z
dc.date.available2019-10-27T08:23:29Z
dc.date.issued2013
dc.departmentEge Üniversitesien_US
dc.description.abstractPurpose: The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients. Methods: 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations. Results: Mean BMI and arm circumference of all participants were 25.0 kg/m2 and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002). Conclusions: Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM. © 2012 Springer Science+Business Media, B.V.en_US
dc.identifier.doi10.1007/s11255-012-0219-8en_US
dc.identifier.endpage1110en_US
dc.identifier.issn0301-1623
dc.identifier.issue4en_US
dc.identifier.pmid22752452en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1103en_US
dc.identifier.urihttps://doi.org/10.1007/s11255-012-0219-8
dc.identifier.urihttps://hdl.handle.net/11454/26434
dc.identifier.volume45en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.relation.ispartofInternational Urology and Nephrologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectArm circumferenceen_US
dc.subjectCuffen_US
dc.subjectHemodialysisen_US
dc.subjectHome blood pressure monitoringen_US
dc.subjectObesityen_US
dc.subjectPeritoneal dialysisen_US
dc.titleArm circumference: Its importance for dialysis patients in the obesity eraen_US
dc.typeArticleen_US

Dosyalar