Multiwalled Carbon Nanotubes-Chitosan Modified Single-Use Biosensors for Electrochemical Monitoring of Drug-DNA Interactions

Küçük Resim Yok

Tarih

2015

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Wiley-VCH Verlag

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

A multiwalled carbon nanotubes (CNT)-chitosan (CHIT) modified pencil graphite electrode (CNT-CHIT/PGE) was developed for the first time herein for electrochemical monitoring of the interaction of an anticancer drug, mitomycin C (MC) and DNA. The characterization of unmodified PGE, CHIT/PGE, CNT/PGE and CHIT-CNT/PGE were performed by scanning electron microscopy and cyclic voltammetry techniques. The oxidation signals of MC and guanine were measured before and after interaction at the surface of CNT-CHIT/PGEs using differential pulse voltammetry. Electrochemical impedance spectroscopy technique was also successfully utilized for monitoring of the interaction process at the surface of CNT-CHIT/PGEs in different interaction times. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Açıklama

Anahtar Kelimeler

Chitosan, Drug-DNA interactions, Electrochemical biosensors, Mitomycin C, Multiwalled carbon nanotubes

Kaynak

Electroanalysis

WoS Q Değeri

Scopus Q Değeri

Q2

Cilt

27

Sayı

8

Künye