Preoperative helical computerized tomography estimation of donor liver volume

Küçük Resim Yok

Tarih

2006

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier Science Inc

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Background. The purpose of this study was to evaluate the accuracy of spiral computed tomography (CT) and 3-D imaging models in measuring total and segmental liver volume in potential living donors. Methods. A prospective study was undertaken to assess the correlation between the volumes of potential donor livers determined via helical CT and the actual volumes measured during operation in 150 donor candidates. Left-lateral segment (S2,3) or left-lobe (S2,3,4) transplantation was performed in 36 cases with 96 right-lobe liver transplants (S5,6,7,8).Ten donor candidates were refused owing to inadequate liver volumes, and 8 for other reasons. Results. The regression analysis model showed a significant correlation between the preoperative CT estimates of graft volume and intraoperative weight measurement of harvested grafts in living liver donors (F:5525.37; P < .05); 97.7% of changes in CT volume were explained by differences in graft mass (R-2:0.977). Conclusion. Preoperative estimation of segmental volumes of the donor liver is necessary to avoid donor-recipient size disparity, thereby preventing hepatic failure of donors after harvesting. It has a major impact on donor selection and type of surgical management. The accuracy of helical CT was high to determine total and segmental liver volumes.

Açıklama

Anahtar Kelimeler

Kaynak

Transplantation Proceedings

WoS Q Değeri

Q3

Scopus Q Değeri

Q3

Cilt

38

Sayı

9

Künye