Avoidable and unavoidable exergy destructions of a fluidized bed coal combustor and a heat recovery steam generator

Küçük Resim Yok

Tarih

2015

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Abstract Advanced exergy analysis was performed using the actual operational data taken from a fluidized bed coal combustor (FBCC) and a heat recovery steam generator (HRSG) in a textile plant located at TorbalI, Izmir. First, the conventional exergy analysis of the units was carried out. The exergetic efficiencies of the units were found to be 44.2% and 46.2%, respectively. Advanced exergy analysis was then performed by splitting the exergy destructions of the units into avoidable and unavoidable parts. The avoidable exergy destruction rates of the FBCC and the HRSG were determined to be 2999 kW and 760 kW according to the measurements. Correspondingly, the exergy efficiencies were modified to 53.1% and 48.1%, respectively. © 2015 Elsevier Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

Advanced exergy analysis, Energy analysis, Exergy analysis, Fluidized bed, Textile plant

Kaynak

Energy Conversion and Management

WoS Q Değeri

Scopus Q Değeri

Q1

Cilt

98

Sayı

Künye