Electrochemical Determination of Dicofol at Nickel Nanowire Modified Poly(p-aminophenol) Film Electrode

Küçük Resim Yok

Tarih

2019

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Wiley-V C H Verlag Gmbh

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

An electrochemical sensor was fabricated by construction of nickel nanowires on the surface of poly(p-aminophenol) (PPAP) modified glassy carbon electrode. The electrochemical response of dicofol, a known pesticide and used for agricultural activities such as cyclic voltammetry and differential pulse voltammetry, were investigated and the results were compared with those obtained unmodified electrodes. Following the optimization of NaOH concentration, polymerization cycle number, Ni nanowire amount, the linear range for the dicofol was studied and found as 0.83-30.7 mu mol L-1 (R-2=0.9981) at Ni/PPAP/GCE with a 0.08 mu mol L-1 detection limit according to S/N=3. Finally, the proposed Ni/PPAP/GCE sensor was successfully applied for the dicofol analysis in soil samples. The characterization of the developed surface was carried out by scanning electron microscopy and X-Ray photoelectron spectroscopy.

Açıklama

Anahtar Kelimeler

Dicofol, p-aminophenol, Nickel nanowire, Polymerization, Pesticide

Kaynak

Electroanalysis

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

31

Sayı

7

Künye