Performance evaluation of a mobile air conditioning unit: an exergetic approach

Küçük Resim Yok

Tarih

2019

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Inderscience Enterprises Ltd

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

This study considers a public bus (having a capacity of 99 passengers and a volume of 69 m(3)) along with its vapour compressed mobile air conditioning (MAC) unit (utilising R134a as a refrigerant) together as a low exergy (so-called LowEx) system. The LowEx analysis, which has been mostly applied to buildings, and conventional exergy analyses method are utilised together (coupled up analysis method) to assess the performance of this system for the first time to the best of the authors' knowledge. Based on the LowEx analysis, total exergy efficiency and exergy flexibility factor are calculated to be 11.92% and 0.56 for the heating mode and 3.41% and 0.19 for the cooling mode, respectively. Furthermore, through on the conventional exergy analyses, the highest exergy efficiency belongs to condenser with 93.08% in the cooling mode, while it is 93.20% for the water heat exchanger in the heating mode, respectively.

Açıklama

Anahtar Kelimeler

low exergy, LowEx, conventional exergy, public bus, mobile air conditioning, MAC, heating and cooling, system performance, exergetic efficiency, exergy flexibility factor

Kaynak

International Journal of Exergy

WoS Q Değeri

Q4

Scopus Q Değeri

Q3

Cilt

28

Sayı

2

Künye