A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods
dc.contributor.author | Ermis, E. E. | |
dc.contributor.author | Pilicer, F. B. | |
dc.contributor.author | Pilicer, E. | |
dc.contributor.author | Celiktas, C. | |
dc.date.accessioned | 2019-10-27T23:09:48Z | |
dc.date.available | 2019-10-27T23:09:48Z | |
dc.date.issued | 2016 | |
dc.department | Ege Üniversitesi | en_US |
dc.description.abstract | The gamma-ray mass attenuation coefficients of blood, bone, lung, eye lens, adipose, tissue, muscle, brain and skin were calculated at different energies (60, 80, 150, 400, 500, 600, 1000, 1250, 1500, and 2000 keV) by various theoretical methods such as FLUKA, GEANT4 Monte Carlo (MC) methods and XCOM program in this work. Calculated coefficients were also compared with the National Institute of Standards and Technology (NIST) values. Obtained results were highly in accordance with each other and NIST values. Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons (60, 80, and 150 keV) when compared with the NIST values. | en_US |
dc.description.sponsorship | Scientific Research 277 Project of Ege University [2014 FEN 026]; Scientific Research 278 Uludag University [OUAP(F)-2012/26] | en_US |
dc.description.sponsorship | This study was supported by Scientific Research 277 Project of Ege University under Project No. 2014 FEN 026 and 278 Uludag University under Project No. OUAP(F)-2012/26. | en_US |
dc.identifier.doi | 10.1007/s41365-016-0053-2 | |
dc.identifier.issn | 1001-8042 | |
dc.identifier.issn | 2210-3147 | |
dc.identifier.issn | 1001-8042 | en_US |
dc.identifier.issn | 2210-3147 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.uri | https://doi.org/10.1007/s41365-016-0053-2 | |
dc.identifier.uri | https://hdl.handle.net/11454/52748 | |
dc.identifier.volume | 27 | en_US |
dc.identifier.wos | WOS:000380038900005 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer Singapore Pte Ltd | en_US |
dc.relation.ispartof | Nuclear Science and Techniques | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Gamma-ray mass attenuation coefficient | en_US |
dc.subject | FLUKA | en_US |
dc.subject | GEANT4 | en_US |
dc.subject | XCOM | en_US |
dc.title | A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods | en_US |
dc.type | Article | en_US |