A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods

dc.contributor.authorErmis, E. E.
dc.contributor.authorPilicer, F. B.
dc.contributor.authorPilicer, E.
dc.contributor.authorCeliktas, C.
dc.date.accessioned2019-10-27T23:09:48Z
dc.date.available2019-10-27T23:09:48Z
dc.date.issued2016
dc.departmentEge Üniversitesien_US
dc.description.abstractThe gamma-ray mass attenuation coefficients of blood, bone, lung, eye lens, adipose, tissue, muscle, brain and skin were calculated at different energies (60, 80, 150, 400, 500, 600, 1000, 1250, 1500, and 2000 keV) by various theoretical methods such as FLUKA, GEANT4 Monte Carlo (MC) methods and XCOM program in this work. Calculated coefficients were also compared with the National Institute of Standards and Technology (NIST) values. Obtained results were highly in accordance with each other and NIST values. Our results showed that FLUKA was quite convenient in comparison to GEANT4 in the calculation of the mass attenuation coefficients of the used human body samples for low-energy photons (60, 80, and 150 keV) when compared with the NIST values.en_US
dc.description.sponsorshipScientific Research 277 Project of Ege University [2014 FEN 026]; Scientific Research 278 Uludag University [OUAP(F)-2012/26]en_US
dc.description.sponsorshipThis study was supported by Scientific Research 277 Project of Ege University under Project No. 2014 FEN 026 and 278 Uludag University under Project No. OUAP(F)-2012/26.en_US
dc.identifier.doi10.1007/s41365-016-0053-2
dc.identifier.issn1001-8042
dc.identifier.issn2210-3147
dc.identifier.issn1001-8042en_US
dc.identifier.issn2210-3147en_US
dc.identifier.issue3en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.urihttps://doi.org/10.1007/s41365-016-0053-2
dc.identifier.urihttps://hdl.handle.net/11454/52748
dc.identifier.volume27en_US
dc.identifier.wosWOS:000380038900005en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSpringer Singapore Pte Ltden_US
dc.relation.ispartofNuclear Science and Techniquesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGamma-ray mass attenuation coefficienten_US
dc.subjectFLUKAen_US
dc.subjectGEANT4en_US
dc.subjectXCOMen_US
dc.titleA comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methodsen_US
dc.typeArticleen_US

Dosyalar