Exergoeconomic Analysis of a Heat Pump Tumbler Dryer

dc.contributor.authorGanjehsarabi, Hadi
dc.contributor.authorDincer, Ibrahim
dc.contributor.authorGungor, Ali
dc.date.accessioned2019-10-27T22:05:26Z
dc.date.available2019-10-27T22:05:26Z
dc.date.issued2014
dc.departmentEge Üniversitesien_US
dc.description.abstractIn this study, exergy and exergoeconomic analyses of a heat pump tumbler dryer are carried out by using actual thermodynamic and cost data. The wet cotton fabric is used as the test drying material. The results show that the specific moisture extraction rate (SMER) and evaporation rate of dryer are equal to 1.08kg/kWh and 0.018kg/s, respectively. Also, the respective exergetic efficiencies of the heat pump and overall system are equal to 0.07 and 0.11. A parametric study is then conducted in order to investigate the system performance and costs of the components, depending on the operating temperature and mass flow rate of air.en_US
dc.identifier.doi10.1080/07373937.2013.829853
dc.identifier.endpage360en_US
dc.identifier.issn0737-3937
dc.identifier.issn1532-2300
dc.identifier.issn0737-3937en_US
dc.identifier.issn1532-2300en_US
dc.identifier.issue3en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage352en_US
dc.identifier.urihttps://doi.org/10.1080/07373937.2013.829853
dc.identifier.urihttps://hdl.handle.net/11454/48426
dc.identifier.volume32en_US
dc.identifier.wosWOS:000330105700013en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Incen_US
dc.relation.ispartofDrying Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCosten_US
dc.subjectDryingen_US
dc.subjectExergoeconomicsen_US
dc.subjectExergyen_US
dc.subjectHeat pump dryeren_US
dc.titleExergoeconomic Analysis of a Heat Pump Tumbler Dryeren_US
dc.typeArticleen_US

Dosyalar