The effect of BIS usage on anaesthetic agent consumption, haemodynamics and recovery time in supratentorial mass surgery [Supratentoryal kitlelerde cerrahi si{dotless}rasi{dotless}nda BIS kullani{dotless}mi{dotless}ni{dotless}n anestetik ajan tüketimi, hemodinami ve derlenme süresine etkileri]
Küçük Resim Yok
Tarih
2014
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Turkish Anaesthesiology and Intensive Care Society
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Objective: In this study, we aimed to compare Bispectral Index (BIS) monitoring with the conventional anaesthesia approach based on haemodynamic changes in terms of anaesthetic agent consumption,haemodynamic recordings, recovery time and cost. Methods: This study was performed in 82 patients, aged 20 to 60 years, who were operated for supratentorial mass and were graded ASA I or II. Cases were randomly divided into two equal groups. In the standard control group haemodynamic parameters were used to determine depth of anaesthesia and in the BIS group, BIS monitoring was applied. In the BIS group the BIS values were kept between 40 and 60; in the control group haemodynamic changes within the range of +/-20% of initial values were controlled using appropriate anaesthetic practice. Haemodynamic parameters, awakening conditions and drug usage were recorded. Results: The difference between the two groups in terms of timing of eye opening and initial spontaneous breath was not statistically significant. The 'Aldrete' score at the 20th postoperative minute for the BIS group was significantly higher than the score calculated for the control group (p<0.05). Rocuronium consumption (mg kg-1 hr-1) was significantly lower in the BIS group than the control group (p<0.05). Although a statistically significant difference (p<0.05) was found between the two groups in terms of initial heart rate and SpO2 values, there was no clinically significant difference in other haemodynamic parameters. Conclusion: Although using BIS monitoring to evaluate depth of anaesthesia does not bring much benefit versus the use of haemodynamic parameters, it may be beneficial for selected surgeries such as awake craniotomy, for patients with a history of awareness and in haemodynamically unstable patients. © 2014 by Turkish Anaesthesiology and Intensive Care Society.
Açıklama
Anahtar Kelimeler
BIS monitoring, Depth of anaesthesia, Haemodynamics, Neurosurgery
Kaynak
Turk Anesteziyoloji ve Reanimasyon Dernegi Dergisi
WoS Q Değeri
Scopus Q Değeri
N/A
Cilt
42
Sayı
3