Determination and Functional Implementation of Operating Point of a Centrifugal Pump With BLDC Motor

dc.authoridselim, erman/0000-0003-4479-0406
dc.authoridAKIN, Ozkan/0000-0002-2214-3374
dc.authorwosidselim, erman/ACZ-1332-2022
dc.contributor.authorTarhan, Umit
dc.contributor.authorSelim, Erman
dc.contributor.authorAkin, Ozkan
dc.date.accessioned2023-01-12T20:01:22Z
dc.date.available2023-01-12T20:01:22Z
dc.date.issued2022
dc.departmentN/A/Departmenten_US
dc.description.abstractIn the present study, a sensorless method is proposed to determine the operating point on pump curves in a BLDC-driven centrifugal pump, and certain functional implementations of the operating point are investigated. To develop a sensorless system, a calibration method is defined for the setup time. System variables such as head, flow, and power are determined at runtime based on the calibration data and the control algorithm of the BLDC motor. Thus, beneficial improvements are achieved for centrifugal pump systems, since only motor phase current sensors are required at runtime. These parameters are used to force the system into various modes such as minimum energy, maximum efficiency, or fastest, which could be selected by the user. The experimental results for an open-loop pump system setup as a part of the experiment are presented.en_US
dc.identifier.doi10.1109/ICJECE.2022.3141556
dc.identifier.endpage113en_US
dc.identifier.issn2694-1783
dc.identifier.issn2694-1783en_US
dc.identifier.issue2en_US
dc.identifier.startpage105en_US
dc.identifier.urihttps://doi.org/10.1109/ICJECE.2022.3141556
dc.identifier.urihttps://hdl.handle.net/11454/77467
dc.identifier.volume45en_US
dc.identifier.wosWOS:000786699200001en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherIeee Canadaen_US
dc.relation.ispartofIeee Canadian Journal Of Electrical And Computer Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPumpsen_US
dc.subjectBrushless DC motorsen_US
dc.subjectPermanent magnet motorsen_US
dc.subjectSynchronous motorsen_US
dc.subjectLiquidsen_US
dc.subjectEstimationen_US
dc.subjectRotorsen_US
dc.subjectBrushless direct current (BLDC)en_US
dc.subjectcentrifugal pumpen_US
dc.subjectefficiencyen_US
dc.subjectoperating pointen_US
dc.titleDetermination and Functional Implementation of Operating Point of a Centrifugal Pump With BLDC Motoren_US
dc.typeArticleen_US

Dosyalar