Standardized method comparison for ACS:180 plus and immulite sensitive PSA (sPSA) measurement methods
dc.contributor.author | Kurtulmus Y. | |
dc.contributor.author | Tanyalçin T. | |
dc.contributor.author | Bozkaya G. | |
dc.contributor.author | Gündüz O. | |
dc.contributor.author | Çerçi Ö. | |
dc.contributor.author | Kutay F.Z. | |
dc.contributor.author | Ersöz B. | |
dc.date.accessioned | 2019-10-27T09:00:13Z | |
dc.date.available | 2019-10-27T09:00:13Z | |
dc.date.issued | 2001 | |
dc.department | Ege Üniversitesi | en_US |
dc.description.abstract | The aim of this study was to compare two immunoassay measurement methods, the ACS: 180 Plus (Chiron Diagnostics) kit and the Immulite sPSA (DPC) kit. Method comparison analysis was performed according to EP9-A; approved guideline of NCCLS 51. Serum samples having a wide range of total prostate-specific antigen (PSA) concentrations were evaluated in split-sample analysis. F-test, t-est analysis and regression statistics were performed. In Deming regression analysis the coefficients were as follows; the slope=0.967; y-intercept=-0.148, r=0.989. An acceptable bias was seen since the systematical error was calculated to have a value less than the total allowable error calculated from biological variations. Nonparametric evaluation of the area under ROC curves for ACS: 180 Plus and Immulite sPSA were 0.997 and 0.987, respectively. Diagnostic accuracy was at the level of p= 0.000 and no statistical difference was found between the two assay methods. | en_US |
dc.identifier.doi | 10.1007/PL00010466 | |
dc.identifier.endpage | 426 | en_US |
dc.identifier.issn | 0949-1775 | |
dc.identifier.issn | 0949-1775 | en_US |
dc.identifier.issue | 09.Oct | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 424 | en_US |
dc.identifier.uri | https://doi.org/10.1007/PL00010466 | |
dc.identifier.uri | https://hdl.handle.net/11454/28015 | |
dc.identifier.volume | 6 | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer New York | en_US |
dc.relation.ispartof | Accreditation and Quality Assurance | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | PSA | en_US |
dc.subject | ROC curve analysis | en_US |
dc.subject | Standardized method comparison | en_US |
dc.title | Standardized method comparison for ACS:180 plus and immulite sensitive PSA (sPSA) measurement methods | en_US |
dc.type | Article | en_US |