The measurement of entrance and exit doses with in-vivo dosimetry in head and neck cancers and comparison with treatment planning doses [Baş-boyun kanserlerinde giriş ve çi{dotless}ki{dotless}ş dozlar{dotless}ni{dotless}n in vivo dozimetri kullani{dotless}larak ölçülmesi ve tedavi planlama dozlari{dotless}yla karşi{dotless}laşti{dotless}ri{dotless}lmasi{dotless}]

dc.contributor.authorPaidar B.
dc.contributor.authorTavlayan E.
dc.contributor.authorOlacak N.
dc.contributor.authorEsassolak M.
dc.contributor.authorAras B.A.
dc.date.accessioned2019-10-26T21:43:52Z
dc.date.available2019-10-26T21:43:52Z
dc.date.issued2012
dc.departmentEge Üniversitesien_US
dc.description.abstractOBJECTIVES We aimed to measure entrance-exit doses using in-vivo dosimetry for head and neck cancer patients and to compare with planning system doses, to facilitate determination of treatment accuracy. METHODS Three diodes were calibrated using water equivalent phantom. Correction factors had been previously assessed for in-vivo diodes and applied to the readings. Dose measurements were performed on 30 treatment setups for 3 patients treated with isocentric, asymmetric left-right two lateral and supraclavicular fields using 6MV. Measured doses were compared with expected doses. RESULTS The results indicated a small acceptable deviation from expected doses. It was found that the mean deviations for entrance and exit doses were 2.3% and 1.9%, respectively. The deviation in the delivered dose is well within the 5% International Commission on Radiation Units and Measurements (ICRU) recommendation, and thus treatment doses are determined to be in accordance with the planning system doses. CONCLUSION It has been shown that in-vivo dosimetry performed using diodes is a reliable and high-precision method for patient dose control. © 2012 Association of Oncology.en_US
dc.identifier.doi10.5505/tjoncol.2012.736
dc.identifier.endpage75en_US
dc.identifier.issn1300-7467
dc.identifier.issn1300-7467en_US
dc.identifier.issue2en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage67en_US
dc.identifier.urihttps://doi.org/10.5505/tjoncol.2012.736
dc.identifier.urihttps://hdl.handle.net/11454/18425
dc.identifier.volume27en_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.relation.ispartofTurk Onkoloji Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHead and neck cancersen_US
dc.subjectIn-vivo diode dosimetryen_US
dc.subjectRadiotherapyen_US
dc.titleThe measurement of entrance and exit doses with in-vivo dosimetry in head and neck cancers and comparison with treatment planning doses [Baş-boyun kanserlerinde giriş ve çi{dotless}ki{dotless}ş dozlar{dotless}ni{dotless}n in vivo dozimetri kullani{dotless}larak ölçülmesi ve tedavi planlama dozlari{dotless}yla karşi{dotless}laşti{dotless}ri{dotless}lmasi{dotless}]en_US
dc.typeArticleen_US