Over-Oxidized Poly (Phenol Red) Film Modified Glassy Carbon Electrode for Anodic Stripping Voltammetric Determination of Ultra-Trace Antimony (III)
dc.contributor.author | Karabiberoglu, Suekriye Ulubay | |
dc.contributor.author | Dursun, Zekerya | |
dc.date.accessioned | 2019-10-27T11:08:47Z | |
dc.date.available | 2019-10-27T11:08:47Z | |
dc.date.issued | 2017 | |
dc.department | Ege Üniversitesi | en_US |
dc.description.abstract | In this study, we introduce a very sensitive and selective method for the differential pulse anodic stripping determination of Sb(III) ion on the over-oxidized poly(phenol red) modified glassy carbon electrode (PPhRed(ox)/GCE) in 0.1 mol L-1 HCl medium. The formation of both poly(phenol red) and over-oxidized poly(phenol red) film on the electrode surfaces were characterized by electrochemical impedance spectroscopy, X-ray photoelectron spectroscopy and scanning electron microscopy techniques. An anodic stripping peak of Sb(III) was observed at 0.015V on the PPhRed(ox)/GCE. Higher anodic stripping peak current of Sb(III) was obtained at PPhRed(ox)/GCE compared with both bare GCE and poly(phenol red) film modified GCE (PPhRed/GCE). The calibration graph consisted of two linear segments of 0.044 - 1.218 g L-1 and 3.40 - 18.26 g L-1 with a detection limit of 0.0075 g L-1. The proposed over-oxidized polymer film modified electrode was applied successfully for the analysis of antimony in different spiked water samples. Spiked recoveries for water samples were obtained in the range of 93.0-103.0%. The accuracy of the method was also verified through the analysis of standard reference materials (SCP SCIENCE-EnviroMAT EP-L-2). | en_US |
dc.description.sponsorship | Ege University Research Funds (BAP) [15 FEN/041] | en_US |
dc.description.sponsorship | This work was supported by Ege University Research Funds (BAP Project No: 15 FEN/041). The authors also acknowledge Associate Prof. Dr. Armaan Knal for careful review of the manuscript. | en_US |
dc.identifier.doi | 10.1002/elan.201600629 | |
dc.identifier.endpage | 1080 | en_US |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.issn | 1040-0397 | en_US |
dc.identifier.issn | 1521-4109 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 1069 | en_US |
dc.identifier.uri | https://doi.org/10.1002/elan.201600629 | |
dc.identifier.uri | https://hdl.handle.net/11454/32213 | |
dc.identifier.volume | 29 | en_US |
dc.identifier.wos | WOS:000398850400020 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wiley-V C H Verlag Gmbh | en_US |
dc.relation.ispartof | Electroanalysis | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Polymer film electrode | en_US |
dc.subject | antimony (III) determination | en_US |
dc.subject | anodic stripping voltammetry | en_US |
dc.subject | SEM | en_US |
dc.subject | XPS | en_US |
dc.title | Over-Oxidized Poly (Phenol Red) Film Modified Glassy Carbon Electrode for Anodic Stripping Voltammetric Determination of Ultra-Trace Antimony (III) | en_US |