Exergy analyses of a tunnel furnace and a tunnel dryer
Küçük Resim Yok
Tarih
2021
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Inderscience Enterprises Ltd
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
The main objective of this study is to comprehensively perform exergy analysis of the tunnel furnace and the tunnel dryer, which was selected as the control volume and involved in a brick production line. The analysis was based on the real data measured over a one-year period at a working brick factory with a daily production capacity of 392 tons of fired bricks. Energy and exergy efficiencies of the control volume were obtained to be 76.46% and 12.90% for dead state values of 25 degrees C and 1.013 atm, respectively.
Açıklama
Anahtar Kelimeler
brick factory, tunnel furnace, tunnel dryer, energy and exergy analysis, Kiln, Optimization, Energy, Fuel
Kaynak
International Journal Of Exergy
WoS Q Değeri
Q4
Scopus Q Değeri
Q3
Cilt
36
Sayı
2-4