Exergy analyses of a tunnel furnace and a tunnel dryer

Küçük Resim Yok

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Inderscience Enterprises Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The main objective of this study is to comprehensively perform exergy analysis of the tunnel furnace and the tunnel dryer, which was selected as the control volume and involved in a brick production line. The analysis was based on the real data measured over a one-year period at a working brick factory with a daily production capacity of 392 tons of fired bricks. Energy and exergy efficiencies of the control volume were obtained to be 76.46% and 12.90% for dead state values of 25 degrees C and 1.013 atm, respectively.

Açıklama

Anahtar Kelimeler

brick factory, tunnel furnace, tunnel dryer, energy and exergy analysis, Kiln, Optimization, Energy, Fuel

Kaynak

International Journal Of Exergy

WoS Q Değeri

Q4

Scopus Q Değeri

Q3

Cilt

36

Sayı

2-4

Künye