Energetic and exergetic performance evaluation of an AC and a solar powered DC compressor

Küçük Resim Yok

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

This study represents experimental performance analyses of an alternative current (AC) and a direct current (DC) refrigeration compressors implemented in a 79 liter refrigerator. Experiments were carried out at continuously running (ON) and periodically running (ON/OFF) operation modes. Data was analyzed and a comparison in terms of cooling capacity, power input, coefficient of performance (COP), Carnot COP, and exergy efficiency was conducted. The comparison showed that DC compressors can be much more efficient than AC compressors in refrigeration units. © Springer-Verlag Berlin Heidelberg 2013.

Açıklama

Anahtar Kelimeler

Compressor, Direct current, Energy saving, Exergy, Solar energy, Variable speed