Yazar "Pinar, Y." seçeneğine göre listele
Listeleniyor 1 - 4 / 4
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Anatomical Foundations of Lower Eyelid Revitalization: Letter on Anatomical Basis for the Lower Eyelid Rejuvenation(Springer, 2023) Govsa, F.; Pinar, Y.[No abstract available]Öğe Is QUALIOST Appropriate for the Patients With Orthotopic Liver Transplantation in Measuring Quality of Life?(Elsevier Science Inc, 2013) Atamaz, F.; Hepguler, S.; Ozturk, C.; Pinar, Y.The quality of life questionnaire in osteoporosis (QUALIOST) measures the impact of this condition. The purpose of this study was to assess the psychometric properties of QUALIOST among 38 orthotopic liver transplantation (OLT) patients who had been diagnosed with osteoporosis or osteopenia versus 42 control subjects with osteoporosis or osteopenia associated with other conditions. Bone mineral density (gr/cm(2)) measurements were performed by dual-energy X-ray absorptiometry as well as thoracic and lumbar spine radiographs to assess fractures. Reliability studies evaluated by intraclass correlation coefficients (ICC) and internal consistency (Cronbach alpha). For the validity studies, correlation analysis was performed between this scale and Short Form-36 (SF-36) results. The questionnaire was filled out completely by all the patients with 0.9% and 1.3% of omitted answer rates for OLT and control patients. ICC and Cronbach's alpha values were good for all domains with values above .90. In both groups we observed significant negative high correlations between the domains of the questionnaire and all SF-36 dimensions (P < .001). At least one vertebral fracture was diagnosed in 17 (44.7%) and 20 (47.6%) patients with OLT and control respectively. The comparison analysis revealed that the scores of QUALIOST of patients with vertebral fracture were significantly higher than those without a fracture in both groups (P < .05). In conclusion, we evaluated the validity and reliability of a scale measuring quality of life in patients who had osteoporosis secondary to OLT. The results showed that the Turkish QUALIOST showed acceptable validity and reliability in these patients.Öğe Is QUALIOST Appropriate for the Patients With Orthotopic Liver Transplantation in Measuring Quality of Life?(Elsevier Science Inc, 2013) Atamaz, F.; Hepguler, S.; Ozturk, C.; Pinar, Y.The quality of life questionnaire in osteoporosis (QUALIOST) measures the impact of this condition. The purpose of this study was to assess the psychometric properties of QUALIOST among 38 orthotopic liver transplantation (OLT) patients who had been diagnosed with osteoporosis or osteopenia versus 42 control subjects with osteoporosis or osteopenia associated with other conditions. Bone mineral density (gr/cm(2)) measurements were performed by dual-energy X-ray absorptiometry as well as thoracic and lumbar spine radiographs to assess fractures. Reliability studies evaluated by intraclass correlation coefficients (ICC) and internal consistency (Cronbach alpha). For the validity studies, correlation analysis was performed between this scale and Short Form-36 (SF-36) results. The questionnaire was filled out completely by all the patients with 0.9% and 1.3% of omitted answer rates for OLT and control patients. ICC and Cronbach's alpha values were good for all domains with values above .90. In both groups we observed significant negative high correlations between the domains of the questionnaire and all SF-36 dimensions (P < .001). At least one vertebral fracture was diagnosed in 17 (44.7%) and 20 (47.6%) patients with OLT and control respectively. The comparison analysis revealed that the scores of QUALIOST of patients with vertebral fracture were significantly higher than those without a fracture in both groups (P < .05). In conclusion, we evaluated the validity and reliability of a scale measuring quality of life in patients who had osteoporosis secondary to OLT. The results showed that the Turkish QUALIOST showed acceptable validity and reliability in these patients.Öğe A morphometric study on the superficial palmar arch of the hand(Springer, 2006) Bilge, O.; Pinar, Y.; Ozer, M. A.; Goevsa, F.The vascular anatomy of the hand is a complex and challenging area and has been the subject of many studies. Knowledge of the vascular patterns and diameters of the hand gained more importance with improvements in microsurgical techniques in reconstructive hand surgery. We evaluated 50 hands (26 left, 24 right) of 26 formalin preserved cadavers to determine the superficial palmar arch, its branches and contributing vessels with special attention to the diameters. The symmetry of the types was also evaluated in detail for the first time in the literature. Measurements were made with the help of a digital caliper. The diameters of the ulnar, radial and median arteries were taken at the level of the wrist while the common palmar digital arteries, hypothenar branches and the superficial palmar branch of the radial artery were measured at their origin. Two types of superficial palmar arch were found and defined as complete (43/50 hands) and incomplete arches (7/50 hands). The complete arches were divided into four subgroups and incomplete arches into three subgroups. Most cases were found at the complete AI group (17 hands). Comparison of the arterial diameters showed the ulnar artery was the dominant vessel of the palm. The diameters of the common palmar digital arteries were not different with regard to complete or incomplete arches and between both sides. It looks safe to sacrifice one of the radial or ulnar arteries in some arterial interventions including radial artery cannulation, radial forearm flap and radial or ulnar artery harvesting for bypass grafting if the arch is complete. But we still recommend the noninvasive tests like modified Allen test or Doppler ultrasonography, before performing an invasive arterial intervention. We propose the radiologists to incorporate the median artery into the Doppler dynamic test in particular the existence or the absence of anastomoses between radial and ulnar arteries.