Yazar "Peskersoy C." seçeneğine göre listele
Listeleniyor 1 - 4 / 4
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Comparative clinical evaluation of the efficacy of a new method for caries diagnosis and excavation(Medknow Publications, 2015) Peskersoy C.; Turkun M.; Onal B.Aim: The purpose of this study is to compare the efficiency of fluorescence-aided caries excavation (FACE) to remove carious dentin primary teeth with that of conventional methods. Methods and Materials: After caries excavation was carried out, dentin surfaces were conventionally inspected using visual tactile criteria and 415 cavities which were classified as caries-free, re-inspected with Face-Light and caries detector dye (CDD) methods. Orange-red fluorescing areas classified as carious dentin, as well as stained carious dentin. All the data were recorded according to localization of the caries and determination efficiency of the methods. X 2 test was used to compare the mean values of both Face-Light and dye applications, while Wilcoxon test performed to evaluate the effectiveness for each diagnostic method. Results: A total of 273 patients with 415 Class II (OM/OD) cavities (1.65 ± 0.52 teeth per patient) with carious lesions in molar and premolar teeth, were examined. Out of 415 teeth, in 149 teeth (35.9%) no caries findings had been illustrated. While FACE detected remaining carious or partially removed areas in 237 teeth (57.2%), CDD stained only 29 teeth by itself (P < 0.05). Conclusion: In conclusion, FACE has a higher detectability compared to visual inspection and caries detector dye in diagnosis and removal of carious dentin.Öğe The Effect of Flowable Composite Resins on Periodontal Health, Cytokine Levels, and Immunoglobulins(Hindawi Limited, 2022) Peskersoy C.; Oguzhan A.; Gurlek O.Objective. This study investigated the effects of flowable resin composites (FCR) on the restoration of noncarious cervical lesions (NCCL) and their impact on periodontal tissues. Materials and Methods. 30 periodontally healthy patients were assigned into three groups randomly; group VF: self-adhering FCR, group NF: fluoride-releasing FCR, and group SF: microhybrid FCR. Gingival crevicular fluid (GCF) volume levels of osteoprotegerin (OPG), immunoglobulins (IgA, IgM), and interleukins (IL-1, IL-1?, and IL-10) in GCF were analyzed with ELISA tests. Clinical success rates were evaluated using USPHS criteria during the 12-month follow-up. Results. The GCF volume was increased mostly in group SF (1.34±0.09 ?l). While the titer of interleukin was increased in all groups, higher increases were observed in IL-1 and IL-1? in group NF (170.78 pg/ml and 39.35 pg/ml). Increased IL-10 was observed in group VF (14.33±0.85 pg/ml). IgA levels varied partially among all groups (p>0.05), and even IgM levels were elevated immediately after the restoration process but returned to normal on the 28th day (p<0.05). Group NF failed in most of the USPHS criteria, while the material group VF and group SF presented acceptable results except in the marginal adaptation criterion (p<0.05). Conclusions. Clinical efficacy of self-adhering FCR was found the best for restoration of NCCL while fluoride-releasing FCR stimulated the periodontal response and had negative effects on GCF volume, cytokine, and immunoglobulin levels. © 2022 Cem Peskersoy et al.Öğe Evaluation of the apical adaptation performance of various root canal instruments(2013) Ceyhanli K.T.; Turkun M.; Erdilek N.; Peskersoy C.; Kose T.Objective: The aim of this study was to evaluate the apical root canal adaptation performance of various root canal instruments. Materials and Methods: A total of 40 freshly extracted single-rooted mandibular incisors were used in this study. Coroner parts of all teeth were removed from cemento-enamel junction and root canal of each tooth was explored with a size 8 K-file until the tip of the file was just visible at the apex. Working lengths (WLs) were determined as 1 mm short of these measurements. ProTaper, K-file, profile and hedstroem files were inserted into the root canals of 10 teeth to the WL following the flaring of the coronal and middle thirds. Instruments were fixed in the root canals with acrylic resin. The apical 1 mm of each root tip was ground on wet sandpaper to expose the canal and the instrument at the WL and the apical region of each tooth was examined under stereomicroscope. The stereoscopic images of the teeth were digitized and analyzed with software in order to determine the differences between the areas of root canals and file tips. Result data were analyzed using the one-way analysis of variance test (P = 0.05). Results: There were no significant differences between apical file/root canal areas of the evaluated instruments (P > 0.05). Conclusions: None of the evaluated instruments performed a perfect adaptation with the apical root canal surface at the WL in mandibular incisors. Therefore, total removal of the debris from the apical canal surface may not be achieved when these filing instruments are used. © 2013 Dental Investigations Society.Öğe Spectrophotometric and computerized evaluation of tooth bleaching employing 10 different home-bleaching procedures: In-vitro study(Dental Investigations Society, 2014) Peskersoy C.; Tetik A.; Ozturk V.O.; Gokay N.Objective: The aim of this in-vitro study was to evaluate the efficacy of bleaching products, determine the applicability and validation of the measurement methods. Materials and Methods: Freshly extracted 110 human incisor teeth were stained with whole blood and hemolysate solution prior to the application of 10 different home-bleaching products. Spectrophotometric measurements of the tooth shades were performed for each specimen before and after bleaching at the 1st, 3rd, 7th, and 14 days. Differences in lightness (?l), chroma (?c), hue (?h) values and shade changes were measured to evaluate process. Computerized digital imaging analyses to determine the color changes were performed with Photoshop CS4 software (Adobe, San Jose, CA, USA). Statistical analyses were performed with analysis of variance, Scheffe and Tukey tests. Results: In all of the test groups regardless of the material used, a significant increase in lightness and hue, and decrease of chroma were observed, as compared to the control group. After recommended bleaching applications, ?l and ?h values respectively increased in group Zaris White and Brite (ZWB) and group Pola Night and ?c values showed significant decrease in groups ZWB and Rembrandt REM3 (P < 0.05). At the end of the procedure both spectrophotometric and digital imaging analysis showed ZWB was the most effective product among the others while Yotuel and Happy Smile were the least (P < 0.05). Conclusions: Home-bleaching systems showed slower but almost permanent bleaching effect likewise office-based methods. Both software and spectrophotometric analyses have advantages such as evaluating the results objectively and numerically, also treatment outcomes could be preserved. © 2014 Dental Investigations Society.