Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Karahan, Zeynep Ceren" seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    HEV seroprevalence in blood donors in Turkey: Comparison of two commercial anti-HEV total Ab ELISA kit
    (Elsevier Science Bv, 2019) Yasar, Osman; Cengiz, Guniz; Karatayli, Ersin; Kizilpinar, Mehtap; Yurdcu, Esra; Albayrak, Rabia; Guven, Aysel; Arslan, Onder; Karahan, Zeynep Ceren; Otlu, Baris; Guducuoglu, Huseyin; Gokahmetoglu, Selma; Berk, Elife; Gitmisoglu, Ozlem; Sertoz, Ruchan; Yurdaydin, Cihan; Mithat, Bozdayi; Karatayli, Senem Ceren
  • Küçük Resim Yok
    Öğe
    Sensitivity Affected by Disease Severity and Serum Sampling Time: a Performance Evaluation of Six SARS-CoV-2 Antibody Immunoassays
    (Natl Inst Infectious Diseases, 2022) Sener, Burcin; Kirbas, Ekin; Sancak, Banu; Gozalan, Aysegul; Evren, Ebru; Karahan, Zeynep Ceren; Zeytinoglu, Aysin
    Comparative validation and clinical performance data are essential for the reliable interpretation of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibody test results. This study aimed to assess the performance of six SARS-CoV-2 IgG immunoassays in the context of different disease severities. Four automated chemiluminescence immunoassays (Access [Beckman Coulter], Architect [Abbott], Atellica-IM [Siemens], and Elecsys [Roche]) as well as two ELISA assays (SARS-CoV-2 IgG-S1-based and NCP IgG [Euroimmun]) were evaluated using samples from 143 patients as well as 50 pre-pandemic control serum samples. Accuracy and precision tests were performed for validation purposes. Overall sensitivity ranged between 73.38-88.65% and was higher in spike protein-based assays, while the specificity was >= 98% in all immunoassays. The clinical performance of the immunoassays differed depending on disease severity and target antigen. For instance, the IgG response was lower for samples taken <20 days post-symptom onset (87.30%) compared with those taken >= 20 days post-symptom onset (94.80%). Moreover, moderate disease levels led to the highest levels of IgG. Higher levels of antibodies were detected in the clinically moderate disease group. In asymptomatic and mild groups, more antibody positivity was detected with spike protein-based assays. All the assays tested could be used to detect SARS-CoV-2 IgG. However, spike based assays revealed relatively higher sensitivity rates than nucleoprotein-based assays, particularly in cases of asymptomatic and mild disease.

| Ege Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Ege Üniversitesi Rektörlüğü Gençlik Caddesi No : 12 35040 Bornova - İZMİR, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim