Kabay, NArda, MKurucaovali, IErsoz, EKahveci, HCan, MDal, SKopuzlu, SHaner, MDemircioglu, MYuksel, M2019-10-272019-10-2720030011-91640011-9164https://doi.org/10.1016/S0011-9164(03)00439-9https://hdl.handle.net/11454/37672European Conference on Desalination and the Environment -- MAY 04-08, 2003 -- MALTAIn this study, separation performance for monovalent salts (NaCl, KCl) and divalent salts (CaCl2 MgCl2) was investigated by electrodialysis at pH 6.0-6.5, 4.0 and 2.0 using constant voltage mode of operation. TS-1-10 electrodialysis equipment (Tokuyama) modified with rotameters was employed in "experimental studies. The effect of electrical potential, pH and ion valency on separation performance was studied at room temperature using a constant flow rate. The efficiencies of each run were evaluated as specific power consumption with the electrical energy consumed only in stack.en10.1016/S0011-9164(03)00439-9info:eu-repo/semantics/closedAccesselectrodialysismonovalent saltsdivalent saltsdesalinationfeed characteristicsspecific power consumptionEffect of feed characteristics on the separation performances of monovalent and divalent salts by electrodialysisArticle15801.Mar95100WOS:000183886300016Q1Q2