Decoupling Capacitor Selection in DCM Flyback PV Microinverters Considering Harmonic Distortion
Küçük Resim Yok
Tarih
2013
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Ieee-Inst Electrical Electronics Engineers Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Electrolytic capacitors as a decoupling reservoir restrict the lifetime of photovoltaic (PV) microinverters. This has led to the development of several improved decoupling circuits that can reduce the capacitor value to allow the use of nonelectrolytic types. In this paper, the minimum decoupling capacitor value for the proper operation of discontinuous conduction mode flyback PV microinverters is analyzed by taking into account the total harmonic distortion (THD) and PV power utilization ratio. The results presented show that the decoupling capacitor value influences the THD more than PV power utilization. A decoupling capacitor selection method for single-stage and two-stage flyback inverters is proposed. Experimental results obtained on an 80-W test bench are presented.
Açıklama
Anahtar Kelimeler
DC-AC power conversion, harmonic analysis, solar power generation
Kaynak
Ieee Transactions on Power Electronics
WoS Q Değeri
Q1
Scopus Q Değeri
N/A
Cilt
28
Sayı
2