Nd: YAG Lazer kapsülotominin görme keskinliği, göz içi basıncı, santral kornea kalınlığı ve refraktif duruma etkisi
dc.contributor.author | Polat, Nihat | |
dc.contributor.author | Tuncer, İbrahim | |
dc.contributor.author | Karahan, Eyyüp | |
dc.contributor.author | Zengin, Mehmet Özgür | |
dc.date.accessioned | 2020-12-01T12:25:17Z | |
dc.date.available | 2020-12-01T12:25:17Z | |
dc.date.issued | 2014 | |
dc.department | Ege Üniversitesi | en_US |
dc.description.abstract | Amaç: Neodymium: yttrium-aluminum-garnet (Nd: YAG) lazer kapsülotomi öncesi ve sonrasında görme keskinliği, göz içi basıncı (GİB), santral kornea kalınlığı (SKK) ve sferik ekivalan (SE) değişimlerinin değerlendirilmesi. Gereç ve Yöntem: Arka kapsül kesafeti bulunan 68 (40 erkek, 28 kadın) hastanın 68 gözü çalışmaya dahil edildi. Gereken en az enerji ve şut sayısıyla Nd: YAG lazer kapsülotomi uygulandı. İşlem öncesi ve sonrasında birinci hafta, birinci ay ve üçüncü ay tüm hastalara en iyi düzeltilmiş görme keskinliği (EDGK), SE, GİB ve SKK ölçümleri yapıldı. Veriler istatistiksel olarak analiz edildi. Bulgular: Lazer sonrası görme keskinliklerinde lazer öncesine göre artış gözlendi. Lazer öncesi ve lazer kapsülotominin birinci ay ve üçüncü ay sonrası sonuçlar arasında anlamlı bir artış mevcuttu (p<0,05). Lazer kapsülotominin birinci haftası ile birinci ay ve üçüncü ay sonrası sonuçlar arasında anlamlı fark yoktu (p>0,05). Lazer öncesi ortalama SE değerlerinde lazer sonrasına göre hipermetropik yöne kayma izlendi. Lazer öncesi ve lazer kapsülotominin birinci hafta, birinci ay ve üçüncü ay sonrası sonuçlar arasında anlamlı bir artış mevcuttu (p<0,001). Lazer kapsülotominin birinci haftası ile birinci ay ve üçüncü ay sonrası sonuçlar arasında anlamlı fark yoktu (p=0,068 ve p=0,541 sırasıyla). Lazer öncesi ortalama SKK ve lazer kapsülotominin birinci hafta sonrası sonuçlar arasında anlamlı bir artış mevcuttu (p<0,001). Lazer öncesi ve lazer kapsülotominin birinci ay ve üçüncü ay sonrası sonuçlar arasında anlamlı fark yoktu (p=0,296 ve p=0,304 sırasıyla). Lazer öncesi GİB ölçümü ve lazer kapsülotominin birinci hafta sonrası sonuçlar arasında anlamlı bir artış mevcuttu (p<0,001). Lazer öncesi ve lazer kapsülotominin birinci ay ve üçüncü ay sonrası sonuçlar arasında anlamlı fark yoktu (p=0,438 ve p=0,664 sırasıyla). Sonuç: Nd: YAG lazer arka kapsülotomi yapılan hastalarda özellikle ilk hafta da görme keskinliği, GİB, SKK ve SE değerlerinde önemli değişiklikler izlenmektedir. (Turk J Ophthalmol 2014; 44: 275-9) | en_US |
dc.description.abstract | Objectives: To evaluate the changes in best-corrected visual acuity (BCVA), intraocular pressure (IOP), central corneal thickness (CCT), and spherical equivalent (SE) before and after Nd: YAG laser capsulotomy. Materials and Methods: This study included 68 patients (40 men, 28 women) who had posterior capsule opacification. the subjects underwent Nd: YAG laser capsulotomy with a minimal energy and shooting number. BCVA, IOP, CCT, and SE were measured before and 1 week, 1 and 3 months after laser capsulotomy. the post-treatment measurements were compared with the pre-treatment ones statistically. Results: There were statistically significant differences between pre- and post-laser BCVA values at 1 week, 1 month, and 3 months (p<0.05). BCVA measurement at 1 week was not statistically significantly different from those at 1 and 3 months (p>0.05). There were statistically significant differences between pre- and post-laser SE values at 1 week, 1 month, and 3 months (p<0.001). the SE value at 1 week was not statistically significantly different from those at 1 and 3 months (p=0.068 and p=0.541, respectively). There were statistically significant differences between pre- and post-laser CCT values at 1 week, 1 month, and 3 months (p<0.001), however, no statistically significant differences were found between the CCT measurement at 1 week and those at 1 and 3 months (p=0.296 and p=0.304, respectively). There were statistically significant differences between pre- and post-laser IOP values at 1 week, 1 month, and 3 months (p<0.001), while there were no statistically significant differences between IOP measurements at 1 week and those at 1 and 3 months (p=0.438 and p=0.664, respectively). Conclusion: Substantial changes were observed, especially at first postoperative week, for BCVA, IOP, CCT, and SE in patients with posterior capsule opacification who underwent Nd: YAG laser capsulotomy. (Turk J Ophthalmol 2014; 44: 275-9) | en_US |
dc.identifier.endpage | 279 | en_US |
dc.identifier.issn | 1300-0659 | |
dc.identifier.issn | 2147-2661 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 275 | en_US |
dc.identifier.uri | https://app.trdizin.gov.tr//makale/TVRZek5qRTVPUT09 | |
dc.identifier.uri | https://hdl.handle.net/11454/65224 | |
dc.identifier.volume | 44 | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.language.iso | tr | en_US |
dc.relation.ispartof | Türk Oftalmoloji Dergisi | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Göz Hastalıkları | en_US |
dc.title | Nd: YAG Lazer kapsülotominin görme keskinliği, göz içi basıncı, santral kornea kalınlığı ve refraktif duruma etkisi | en_US |
dc.title.alternative | The Effect of Nd: YAG Laser capsulotomy on visual acuity, ıntraocular pressure, central corneal thickness, and refractive status | en_US |
dc.type | Article | en_US |