Energy and exergy analysis of the Gonen geothermal district heating system, Turkey

Küçük Resim Yok

Tarih

2005

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Pergamon-Elsevier Science Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

This paper describes a performance evaluation of the Gonen geothermal district heating system (GGDHS) in Balikesir, Turkey, based on energy and exergy analyses. The exergy destructions in the overall GGDHS are quantified and illustrated using energy and exergy flow diagrams for a reference temperature of 6 degrees C. The results indicate that the exergy destructions in the system occur primarily as a result of losses in the pumps, heat exchangers, and pipelines, as well as losses associated with cooled geothermal waters injected back into the reservoir. These losses amount to 14.81%, 7.11%, 1.06%, and 12.96% of the total exergy input to the GGDHS, respectively. Both energy and exergy efficiencies of the overall GGDHS were investigated to analyze and improve system performance. The efficiencies were determined to be 45.91 % and 64.06%, respectively. (c) 2005 CNR. Published by Elsevier Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

geothermal energy, geothermal district heating, energy analysis, exergy analysis

Kaynak

Geothermics

WoS Q Değeri

Q3

Scopus Q Değeri

N/A

Cilt

34

Sayı

5

Künye