A Collapsible Partial Denture for a Patient with Limited Mouth Opening Induced by Scleroderma: A Clinical Report
Küçük Resim Yok
Tarih
2015
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Wiley
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
A limited opening of the mouth is defined as microstomia. Microstomia is caused by burns, postoperative head and neck trauma, radiotherapy, or scleroderma. The prosthetic treatment of microstomia presents particular challenges, and patients often complain of an inability to insert or remove the prosthesis. The cause and severity of microstomia can influence the approach to treatment. Different treatment methods have been suggested, including the fabrication of two-piece partial dentures. This clinical report describes the construction of a sectional impression tray and a collapsed partial denture using a hinge attachment for a patient with microstomia.
Açıklama
Anahtar Kelimeler
Microstomia, scleroderma, collapsible partial denture, hinge attachment
Kaynak
Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry
WoS Q Değeri
Q3
Scopus Q Değeri
Q1
Cilt
24
Sayı
4