Relationship between the serum digoxin level and left ventricular ejection time

Küçük Resim Yok

Tarih

1978

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Correlation between the difference obtained from the determination of left ventricular ejection time before and after digitalisation and digoxin level was investigated. It was concluded that the determination of the decrease in the value of left ventricular ejection time following digitalisation period is a limited and rough method for the determination of serum digoxin level.

Açıklama

Anahtar Kelimeler

Kaynak

Aegean Medical Journal

WoS Q Değeri

Scopus Q Değeri

N/A

Cilt

7

Sayı

2

Künye