Study on Labeling Conditions of I-125 Synkavit By the Iodogen Method
Küçük Resim Yok
Tarih
1994
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Akademiai Kiado
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Labeling conditions of synkavit (2-methyl-1,4-naphthoquinol disodium phosphate) with iodine-125 have been studied. In this study, labeling temperature, reaction time, successive using of iodogen coated tubes, iodogen amount and synkavit concentrations have been determined to get optimum conditions for maximum labeling. Final results showed that when the labeling temperature, reaction time, synkavit concentration, and iodogen amount were, at room temperature, 15 min (in the case of successive using of three iodogen coated tubes), 2 mg ml-1 and 5 mg, respectively; labeling yield was 90% and specific activities of the order of 555 GBq mmol-1 (15 Ci mmol-1) have been obtained.
Açıklama
Anahtar Kelimeler
Kaynak
Journal of Radioanalytical and Nuclear Chemistry-Letters
WoS Q Değeri
N/A
Scopus Q Değeri
Cilt
187
Sayı
4