Some microdosmetric data on Astatine-211

Küçük Resim Yok

Tarih

2003

Yazarlar

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Pergamon-Elsevier Science Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Radionuclides which emit short range, high LET radiations such as alpha and Auger electrons have very promising applications in cancer therapy, Such radionuclides should eventually be incorporated into cell nuclei to achieve high radiotoxic effectiveness. This means that the dose distribution within the cell nucleus at microscopic levels is very important for comparison of the real differences between the radiotoxic effectiveness of different radionuclides. An experimental setup to determine real dose absorption on the microscopic scale is extremely difficult to design. For this reason, calculation procedures for microscopic dose absorption are of special interest for the diagnostic and therapeutic applications of radionuclides which emit short-range and high LET radiations. A specific calculation method for microscopic energy absorptions within the cell nucleus from Auger electrons of (125)I was described earlier. In this study, the radiotoxic effectiveness of (211)At and (125)I has been compared using the data obtained by this calculation method. The data obtained show clearly that the radiotoxicity of the alpha and Auger emitter radionuclide (211)At is comparable to that of (125)I. (C) 2002 Elsevier Science Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

Kaynak

Applied Radiation and Isotopes

WoS Q Değeri

Q2

Scopus Q Değeri

Q3

Cilt

58

Sayı

1

Künye