A comparative study of Ti+N and W ion implantation into Ti-6Al-4V alloy

Küçük Resim Yok

Tarih

2007

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Elsevier Science Sa

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

The effect of Ti + N hybrid ion implantation and W ion implantation at a dose of 1 X 10(17) ions/cm(2), and 50 kV and 40 W extraction voltage on mechanical properties of Ti-6Al-4V samples was studied. Mechanical tests have shown that the friction coefficient decreased with both Ti + N and W ion implantations. It was observed that the Ti + N hybrid ion implanted samples gave better results compared to those of the W ion implanted ones. The results of wear tests showed that both Ti + N hybrid and W ion implanted samples had much better wear resistance compared to unimplanted samples. Hardness values for Ti + N hybrid ion implanted and W implanted samples were much higher than those for unimplanted ones. Ti + N and W ions charge state distributions were measured using time of flight spectrometry. W concentration profiles were obtained by Rutherford backscattering spectrometry. These and the range distribution of ions in implanted and unimplanted samples were evaluated using TRIM and STOPPO programs.

Açıklama

14th International Conference on Surface Modification by Ion Beams (SMMIB 05) -- SEP 04-09, 2005 -- Kusadasi, TURKEY

Anahtar Kelimeler

ion implantation, wear, surface modification

Kaynak

Surface & Coatings Technology

WoS Q Değeri

Q1

Scopus Q Değeri

Cilt

201

Sayı

19-20

Künye