Comparative assessment of pulsed electromagnetic fields (PEMF) and pulsed radio frequency energy (PRFE) on an in vitro wound healing model

Küçük Resim Yok

Tarih

2018

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Ios Press

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Pulsed electromagnetic fields (PEMF) and pulsed radio frequency energy (PRFE) have been shown to accelerate wound healing process due to its ability to stimulate cellular proliferation. However, comparative efficacy of PEMF and PRFE on an in vitro wound healing study has yet to be studied. The present study examined the effect of PEMF and PRFE on an in vitro wound healing model developed by using 3T3 mouse fibroblasts. Cells were exposed to PEMF (75 Hz frequency, square waveform, and 1-mT magnetic field) and PRFE (27.12 MHz, Phase-shift keying (PSK), and 13-dBm amplitude signal) for 5 hours. The migration rates of 3T3 fibroblasts were determined by capturing images at time points of 0, 12, 24, 48, and 72 hours. Cell proliferation was also quantified. The results of the migration and proliferation assays showed that PEMF and PRFE applied groups had significantly greater cell proliferation and migration compared to control group. In addition, PRFE application showed significantly faster wound area closure compared to PEMF application.

Açıklama

Anahtar Kelimeler

Pulsed radio frequency energy (PRFE), pulsed electromagnetic fields (PEMF), wound healing, rectangular spiral applicator

Kaynak

International Journal of Applied Electromagnetics and Mechanics

WoS Q Değeri

N/A

Scopus Q Değeri

Q3

Cilt

57

Sayı

4

Künye