The Effect of Ceramic Restoration Shade and Thickness on the Polymerization of Light- and Dual-cure Resin Cements

Küçük Resim Yok

Tarih

2011

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Operative Dentistry Inc

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Objectives: Inadequately polymerized resin cements may negatively affect the clinical performance of cemented all-ceramic restorations. The purpose of this in vitro study was to evaluate the effect of ceramic thickness and shade on the microhardness of various light-cured (LC) and dual-cured (DC) resin cements. The amount of light transmission through the restoration was also evaluated to correlate the results. Methods: Three different brands of resin cements (Appeal/Ivoclar; Calibra/Dentsply; Nexus 2/Kerr) were used in LC and DC forms to prepare disk-shaped samples (0.5-mm thickness x 5-mm diameter) (n=15). Study group samples were light-cured for 40 seconds (Flash-lite 1401/Discus Dental) through four shades (ETC1, ETC2, ETC3, ETC4) and four thicknesses (1 mm, 2 mm, 3 mm, 4 mm) of all-ceramic ingot discs (IPS Empress Esthetic/Ivoclar). Control samples were directly cured without the presence of ceramic. The light transmission through various shades and thicknesses of ceramics was measured using a hand-held radiometer (Demetron, Kerr). Vickers microhardness measurements were performed (Micromet/Buehler) at 24 hours following dark storage in 37 degrees C water. Correlation between ceramic shade, thickness, and light intensity readings (mW/cm(2)) with respect to microhardness was statistically evaluated using analysis of variance (p=0.05). Results: Ceramic thickness of 3 mm and/or above significantly decreased the microhardness values in all LC and DC groups (p<0.0001). Ceramic shade had a significant effect only on Calibra in both LC and DC groups (p<0.0001). Microhardness values of LC groups were significantly lower than DC groups (p<0.0001). Control groups had significantly higher hardness values in all cement groups (p<0.0001). There was a significant correlation between the amount of light transmitted and hardness (p=0.000). Conclusion: The ceramic thickness has a more intense effect on polymerization compared to the ceramic shade. Overlying ceramic thickness of 3 mm and above was found to adversely affect the polymerization of LC and DC resin cements and therefore a 3-mm thickness was considered the critical threshold.

Açıklama

Anahtar Kelimeler

Kaynak

Operative Dentistry

WoS Q Değeri

Q2

Scopus Q Değeri

Q1

Cilt

36

Sayı

6

Künye