Comparison of clinical results between transpulmonary thermodilution monitoring and conventional methods in cardiac surgery: An observational study

Küçük Resim Yok

Tarih

2024

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Lippincott Williams & Wilkins

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

The Pulse Index Contour Continuous Cardiac Output (PICCO) module provides advanced and continuous monitoring of cardiac output through the use of arterial pulse contour analysis and transpulmonary thermodilution. The objective of this study was to compare the early postoperative outcomes of patients who were monitored using the conventional method and the pulse contour analysis method. A prospective observational study was conducted involving 45 patients who underwent cardiac surgery between 2020 and 2022. Patients were randomly assigned to either Group P (PICCO) or Group C (conventional). In the PICCO cohort, a femoral artery cannula was inserted for the continuous recording and management of hemodynamic data, in accordance with the decision-making algorithm of the module. In the conventional group, cannulation of the radial artery and jugular vein was performed. The postoperative hemodynamic and clinical data are subjected to analysis. The utilization of dopamine was markedly diminished in Group P at both the 0- and 6-hour postoperative intervals, whereas the administration of dobutamine was observed to be elevated (P = .008). The frequency of red packed cell transfusions was higher in Group C at postoperative hour 0. Hemodynamic data indicated a 42% increase in cardiac index and a 33% decrease in systemic vascular resistance, along with a 33% increase in global ejection fraction in patients monitored with PICCO. The mortality rates observed in the 2 groups were not statistically different. The implementation of advanced monitoring techniques, specifically the PICCO module, led to notable enhancements in hemodynamic parameters. The utilization of this technique may prove advantageous in guiding inotrope selection and transfusion decisions during the initial postoperative period. However, it is important to note that morbidity and mortality rates remain comparable.

Açıklama

Anahtar Kelimeler

cardiac surgery, goal-directed therapy, hemodynamic management, pulse contour analysis, thermodilution

Kaynak

Medicine

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

103

Sayı

51

Künye

Ertugay, S., Kahraman, U., Oguz, E., Demir, E., Ozturk, E., Kocabas, N. S., Tuncer, O. N., Ozturk, P., & Ozbaran, M. (2024). Comparison of clinical results between transpulmonary thermodilution monitoring and conventional methods in cardiac surgery: An observational study. Medicine (Baltimore), 103(51), e40884.